Refine Results
- 必威体育赛事投注
-
Product Category
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Instrument
-
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机An Agilent Polaris C18-A HPLC column separates eight anti-inflammatory and analgesic drugs in eight minutes.
- Publication Part Number: A02217
- Created: 31 Oct 2011
- 724 KB
Publication Part Number | A02217 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The HPLC of glyburide, an antidiabetic, takes three minutes on an Agilent Polaris C18-A column.
- Publication Part Number: A01996
- Created: 31 Oct 2011
- 439 KB
Publication Part Number | A01996 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates four catechins in three minutes.
- Publication Part Number: A01999
- Created: 31 Oct 2011
- 661 KB
Publication Part Number | A01999 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Fast HPLC analysis of glucocorticoids is carried out using an Agilent Polaris C18-A column.
- Publication Part Number: A02216
- Created: 31 Oct 2011
- 716 KB
Publication Part Number | A02216 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates seven ginsenosides from Panax species (ginseng) in 70 minutes.
- Publication Part Number: A01928
- Created: 01 Oct 2011
- 478 KB
Publication Part Number | A01928 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机LC/MS with an Agilent Polaris C18-A column analyzes cold and cough medicine in less than four minutes.
- Publication Part Number: A01931
- Created: 01 Oct 2011
- 663 KB
Publication Part Number | A01931 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates three 18-carbon fatty acids in under 52 seconds using an isocratic eluent.
- Publication Part Number: A01936
- Created: 01 Oct 2011
- 478 KB
Publication Part Number | A01936 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates eight acidic anti-inflammatory and analgesic drugs in eight minutes.
- Publication Part Number: A01926
- Created: 01 Oct 2011
- 489 KB
Publication Part Number | A01926 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates seven cytokinin antidepressants in 23 minutes._
- Publication Part Number: A01929
- Created: 01 Oct 2011
- 813 KB
Publication Part Number | A01929 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates insulin and an impurity in a sample of bovine serum in six minutes.
- Publication Part Number: A01932
- Created: 01 Oct 2011
- 403 KB
Publication Part Number | A01932 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC using an Agilent Polaris C18-A column separates seven tricyclic antidepressants in 16 minutes.
- Publication Part Number: A01937
- Created: 01 Oct 2011
- 602 KB
Publication Part Number | A01937 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C8-A column separates codeine and ibuprofen in under 60 seconds.
- Publication Part Number: A01927
- Created: 01 Oct 2011
- 519 KB
Publication Part Number | A01927 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates three antibiotics in seven minutes.
- Publication Part Number: A01930
- Created: 01 Oct 2011
- 469 KB
Publication Part Number | A01930 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates two flavonoids from Gingko biloba in six minutes.
- Publication Part Number: A01935
- Created: 01 Oct 2011
- 538 KB
Publication Part Number | A01935 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates four fat-soluble vitamins in 17 minutes.
- Publication Part Number: A01934
- Created: 01 Oct 2011
- 512 KB
Publication Part Number | A01934 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for Reversed-phase Separation of Intact Monoclonal Antibodies
- Publication Part Number: 5990-9016EN
- Created: 30 Sep 2011
- 199 KB
Publication Part Number | 5990-9016EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
A mixture of standard proteins was used to determine the resolution characteristics of the columns...
- Publication Part Number: 5990-8895EN
- Created: 13 Sep 2011
- 703 KB
Publication Part Number | 5990-8895EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Application note for the analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection
- Publication Part Number: 5990-8414EN
- Created: 01 Sep 2011
- 927 KB
Publication Part Number | 5990-8414EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|
The aggregation of protein therapeutics has become a major concern for the
- Publication Part Number: 5990-8613EN
- Created: 02 Aug 2011
- 602 KB
Publication Part Number | 5990-8613EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for trypsin-digested monoclonal antibody and BSA using Agilent ZORBAX RRHD 300SB-C18
- Publication Part Number: 5990-8244EN
- Created: 01 June 2011
- 4 MB
Publication Part Number | 5990-8244EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|