Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
In this application note, pre-packed Bio-monolith Protein A columns, part of the AdvanceBio family, were used to demonstrate the quick capture of monoclonal antibody titer
- Publication Part Number: 5991-2990EN
- Created: 08 Jan 2014
- 441 KB
Publication Part Number | 5991-2990EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent Bio MAb columns, in an Agilent 1260 Infinity Bio-inert Quaternary LC, characterize the charge heterogeneity of IgG1monoclonal antibody...
- Publication Part Number: 5991-0895EN
- Created: 01 Aug 2013
- 240 KB
Publication Part Number | 5991-0895EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Fast and efficient LC TOF/MS characterizes intact and digested IgG to identify glycoform masses and profiles.mAb-glyco chip analysis built a glycan accurate mass database.
- Publication Part Number: 5991-2323EN
- Created: 23 Apr 2013
- 475 KB
Publication Part Number | 5990-2323EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Rapid reversed-phase separations of intact and reduced monoclonal antibodies (mAbs) were optimized using Agilent ZORBAX RRHD 300SB-C3 columns.
- Publication Part Number: 5990-9667EN
- Created: 13 Feb 2012
- 364 KB
Publication Part Number | 5990-9667EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
JM
- Publication Part Number: 5990-9668EN
- Created: 07 Feb 2012
- 807 KB
Publication Part Number | 5990-9668EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
StableBond 300 Å Rapid Resolution (3.5 μm) LC columns with different bonded phases were used to systematically develop a reversed-phase LC/MS method for reduced...
- Publication Part Number: 5989-6840EN
- Created: 27 June 2007
- 203 KB
Publication Part Number | 5989-6840EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|