必威体育登录手机An Agilent Polaris C18-A HPLC column separates eight anti-inflammatory and analgesic drugs in eight minutes.
- Publication Part Number: A02217
- Created: 31 Oct 2011
- 724 KB
Publication Part Number | A02217 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机HPLC analysis of four pain killers is achieved with an Agilent Polaris C18-Ether column in under seven minutes.
- Publication Part Number: A02014
- Created: 31 Oct 2011
- 617 KB
Publication Part Number | A02014 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机An Agilent Polaris C8 HPLC column separates three analgesics in 40 seconds.
- Publication Part Number: A02218
- Created: 31 Oct 2011
- 644 KB
Publication Part Number | A02218 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates eight acidic anti-inflammatory and analgesic drugs in eight minutes.
- Publication Part Number: A01926
- Created: 01 Oct 2011
- 489 KB
Publication Part Number | A01926 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Agilent Pursuit C8 5 µm material in a ChromSep cartridge separates three analgesics in less than five minutes.
- Publication Part Number: A02323
- Created: 11 May 2010
- 465 KB
Publication Part Number | A02323 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Agilent Pursuit C18 5 µm material in a ChromSep cartridge separates three common analgesics in less than five minutes using HPLC.
- Publication Part Number: A02309
- Created: 11 May 2010
- 877 KB
Publication Part Number | A02309 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|