Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Chemical Group
-
- Language
-
Language
Applied Filters
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 22 C1 to C9 hydrocarbons and C6 to C9 aromatics from a BMW car exhaust in 45 minutes.
- Publication Part Number: A0612
- Created: 31 Oct 2011
- 791 KB
Publication Part Number | A00612 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C5 hydrocarbons in exhaust from a gasoline engine in 42 minutes.
- Publication Part Number: A00739
- Created: 31 Oct 2011
- 765 KB
Publication Part Number | A00739 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 81 C1 to C7 hydrocarbons in car exhaust gas in 33 minutes.
- Publication Part Number: A0895
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00895 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C9 hydrocarbons in air in 60 minutes.
- Publication Part Number: A00056
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00056 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|