必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
Publication Part Number | SI-02644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 21 C1 to C6 hydrocarbon impurities in cis-2-butene in 20 minutes.
- Publication Part Number: A01099
- Created: 31 Oct 2011
- 673 KB
Publication Part Number | A01099 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
Publication Part Number | A00755 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 18 saturated and unsaturated C1 to C6 hydrocarbons in seven minutes.
- Publication Part Number: A0121
- Created: 31 Oct 2011
- 616 KB
Publication Part Number | A00121 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00271 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C9 hydrocarbons in air in 60 minutes.
- Publication Part Number: A00056
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00056 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 15 C1 to C4 light hydrocarbons in eight minutes.
- Publication Part Number: A0253
- Created: 31 Oct 2011
- 463 KB
Publication Part Number | A00253 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column separates 20 C1 to C6 hydrocarbons in a reference mixture in 15 minutes.
- Publication Part Number: A01123
- Created: 31 Oct 2011
- 565 KB
Publication Part Number | A01123 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 22 saturated and unsaturated light hydrocarbons in 20 minutes.
- Publication Part Number: A00037
- Created: 31 Oct 2011
- 480 KB
Publication Part Number | A00037 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column indentifies 19 C1 to C7 hydrocarbons in 63 minutes.
- Publication Part Number: A0896
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A00896 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 111components during naphtha and reformate according to ASTM D5134 in 75 minutes.
- Publication Part Number: A0752
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00752 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C1 to C7 hydrocarbons in natural gas in 25 minutes.
- Publication Part Number: A0117
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A00117 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of seven impurities in a hydrocarbon stream is accomplished in less than 12 minutes using the Agilent J&W Select Al2O3 MAPD column.
- Publication Part Number: A02040
- Created: 31 Oct 2011
- 415 KB
Publication Part Number | A02040 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 25 impurities in 1,3-butadiene for an ASTM method, in 30 minutes.
- Publication Part Number: A01544
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A01544 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates 16 C5 to C8 hydrocarbon isomers in 220 seconds.
- Publication Part Number: A01628
- Created: 31 Oct 2011
- 344 KB
Publication Part Number | A01628 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates impurities in propylene in 35 minutes.
- Publication Part Number: A01267
- Created: 31 Oct 2011
- 580 KB
Publication Part Number | A01267 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|