Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Detection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates C1 to C3 hydrocarbons and carbon monoxide/dioxide in six minutes.
- Publication Part Number: A01287
- Created: 18 Oct 2021
- 110 KB
Publication Part Number | A01287 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent J&W CP-Sil 5 CB GC column separates C1 to C4 alkanes, hydrogen sulfide and other components of natural gas
- Publication Part Number: A00001
- Created: 12 Aug 2013
- 537 KB
Publication Part Number | A00001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机A method has been developed for the analysis of permanent gases and hydrocarbons using Agilent Micro-fluidics Capillary Flow Technology (CFT).
- Publication Part Number: 5991-1323EN
- Created: 26 Nov 2012
- 497 KB
Publication Part Number | 5991-1323EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates carbonyl sulfide and ethylene in seven minutes.
- Publication Part Number: A01260
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A01260 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 15 C1 to C5 hydrocarbons and hydrogen sulfide in fuel gas in 16 minutes.
- Publication Part Number: A00574
- Created: 31 Oct 2011
- 665 KB
Publication Part Number | A00574 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates four gases in five minutes.
- Publication Part Number: A0683
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00683 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in five minutes.
- Publication Part Number: A0307
- Created: 31 Oct 2011
- 368 KB
Publication Part Number | A00307 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates carbon dioxide in air in 20 seconds.
- Publication Part Number: A0288
- Created: 31 Oct 2011
- 272 KB
Publication Part Number | A00288 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates six permanent gases in water in four minutes.
- Publication Part Number: A0684
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A00684 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&WCP-Sil 5 CB column determines low levels of formaldehyde in eight minutes.
- Publication Part Number: A01279
- Created: 31 Oct 2011
- 394 KB
Publication Part Number | A01279 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates C2 hydrocarbons to base line in two minutes.
- Publication Part Number: A01587
- Created: 31 Oct 2011
- 382 KB
Publication Part Number | A01587 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in only 3.5 minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02017
- Created: 31 Oct 2011
- 780 KB
Publication Part Number | A02017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column analyzes carbon dioxide and carbon monoxide in hydrocarbon streams in six minutes.
- Publication Part Number: A01431
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A01431 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of permanent gases and CO2 is achieved in two minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02050
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A02050 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight gases and volatiles in 13 minutes.
- Publication Part Number: A01610
- Created: 31 Oct 2011
- 409 KB
Publication Part Number | A01610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column elutes sulfur gases without interference from light hydrocarbons, in ten minutes.
- Publication Part Number: A01292
- Created: 31 Oct 2011
- 791 KB
Publication Part Number | A01292 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three components in an air sample in two minutes.
- Publication Part Number: A0283
- Created: 31 Oct 2011
- 363 KB
Publication Part Number | A00283 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates hydrochloric acid and water in less than seven minutes, withstanding repeated injections of HCl very well.
- Publication Part Number: A01601
- Created: 31 Oct 2011
- 325 KB
Publication Part Number | A01601 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column produces good peak shapes in the analysis of halogenated hydrocarbons.
- Publication Part Number: A01588
- Created: 31 Oct 2011
- 471 KB
Publication Part Number | A01588 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates eight C1 to C4 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0606
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00606 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|