Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 35 solvents in 12 minutes.
- Publication Part Number: A0185
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00185 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 13 trace C1 to C3 hydrocarbon solvents in drinking water in 11 minutes.
- Publication Part Number: A01423
- Created: 31 Oct 2011
- 878 KB
Publication Part Number | A01423 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates seven C4 to C8 ethers in three minutes.
- Publication Part Number: A0180
- Created: 31 Oct 2011
- 508 KB
Publication Part Number | A00180 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01424 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column separates oxygenates in a C1 to C6 hydrocarbon matrix in 23 minutes.
- Publication Part Number: A01362
- Created: 31 Oct 2011
- 887 KB
Publication Part Number | A01362 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Analysis of sulfur and oxygenated compounds on an Agilent J&W Lowox column in 29 minutes.
- Publication Part Number: A02073
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02073 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates 20 C1 – C5 oxygenated compounds in a hydrocarbon matrix in 42 minutes.
- Publication Part Number: A01613
- Created: 31 Oct 2011
- 780 KB
Publication Part Number | A01613 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|