Refine Results
- 必威体育赛事投注
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Instrument
Instrument
- Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Analysis of C1 to C10 Hydrocarbons including C1 to C6 Paraffin/Olefin Isomer Separation at Ambient temperature Using Dual FID and a Capillary Flow Technology Deans Switch
- Publication Part Number: 5991-3253EN
- Created: 27 Sep 2013
- 141 KB
Publication Part Number | 5991-3253EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机USP residual solvents were analyzed by static headspace on the Agilent 7697A Headspace Sampler combined with the Agilent 7890B Gas Chromatograph.
- Publication Part Number: 5991-1834EN
- Created: 29 Jan 2013
- 340 KB
Publication Part Number | 5991-1834EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Russian (Russia) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
- Publication Part Number: 5990-7625CHCN
- Created: 27 Dec 2012
- 863 KB
Publication Part Number | 5990-7625EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
English (United States) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
必威体育登录手机Specifically designed and tested Agilent J&W DB-Select 624UI for USP resolves critical pairs.
- Publication Part Number: 5991-0616EN
- Created: 07 June 2012
- 2 MB
Publication Part Number | 5991-0616EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Gas chromatography using an Agilent J&W CP-SimDist CB UltiMetal column analyzes reference gas oil according to ASTM D2887 in 30 minutes.
- Publication Part Number: A01262
- Created: 31 Oct 2011
- 824 KB
Publication Part Number | A01262 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates 33 solvents in 30 minutes.
- Publication Part Number: A01624
- Created: 31 Oct 2011
- 579 KB
Publication Part Number | A01624 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 24 C6 to C9 hydrocarbons in air in 12.5 minutes.
- Publication Part Number: A01526
- Created: 31 Oct 2011
- 734 KB
Publication Part Number | A01526 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-Sil 5 CB column separate eight volatile alcohols and hydrocarbons in a hexane sample in nine minutes.
- Publication Part Number: A01336
- Created: 31 Oct 2011
- 871 KB
Publication Part Number | A01336 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten C1 to C10 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A0225
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A00225 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 14 C1 to C6 hydrocarbon impurities in 1,3-butadiene in 15 minutes.
- Publication Part Number: A01122
- Created: 31 Oct 2011
- 424 KB
Publication Part Number | A01122 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Squalene column separates a mixture of xylenes and other C6 to C8 aromatic hydrocarbons in 20 minutes.
- Publication Part Number: A0436
- Created: 31 Oct 2011
- 576 KB
Publication Part Number | A00436 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01424 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 14 impurities in propylene in 25 minutes.
- Publication Part Number: A01353
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01353 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates 13 chlorinated fluorocarbons and C1 to C6 hydrocarbons in 15 minutes.
- Publication Part Number: A01429
- Created: 31 Oct 2011
- 721 KB
Publication Part Number | A01429 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates tetrahydrofuran in technical cyclohexane in 20 minutes.
- Publication Part Number: A00005
- Created: 31 Oct 2011
- 564 KB
Publication Part Number | A00005 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00271 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column is used for the trace analysis of acetaldehyde in a hydrocarbon matrix, with separation in 12 minutes.
- Publication Part Number: A01297
- Created: 31 Oct 2011
- 856 KB
Publication Part Number | A01297 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|