Refine Results
- Content Type
-
Content Type
- Chemical Group
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine components from a one-year-old Gouda cheese.
- Publication Part Number: A0847
- Created: 31 Oct 2011
- 709 KB
Publication Part Number | A00847 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 10 components in two Pilsener beers in 27 minutes.
- Publication Part Number: A1026
- Created: 31 Oct 2011
- 544 KB
Publication Part Number | A01026 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates nine alcohols, acetates, aldehydes and dioxane in a whisky in 12 minutes.
- Publication Part Number: A0368
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00368 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine components in a sample of medium-heat milk powder with an oxidation flavor.
- Publication Part Number: A0846
- Created: 31 Oct 2011
- 472 KB
Publication Part Number | A00846 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column produces a fingerprint of apple juice aroma in 30 minutes.
- Publication Part Number: A0851
- Created: 31 Oct 2011
- 818 KB
Publication Part Number | A00851 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 11 components in a sample of yoghurt.
- Publication Part Number: A0845
- Created: 31 Oct 2011
- 481 KB
Publication Part Number | A00845 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|