Refine Results
- 必威体育赛事投注
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Injection Technique
-
- Instrument
-
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC analyzes CFC 11 and CFC 123 in air in 23 seconds.
- Publication Part Number: A0881
- Created: 31 Oct 2011
- 329 KB
Publication Part Number | A00881 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an AgilentJ&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates formaldehyde in air in 30 seconds.
- Publication Part Number: A0989
- Created: 31 Oct 2011
- 514 KB
Publication Part Number | A00989 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates carbon dioxide in air in 20 seconds.
- Publication Part Number: A0288
- Created: 31 Oct 2011
- 272 KB
Publication Part Number | A00288 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with the Agilent 490 Micro GC and an Agilent J&W PoraPLOT Q column checks calibration bottles for the presence of residual solvent in 65 seconds.
- Publication Part Number: A01620
- Created: 31 Oct 2011
- 370 KB
Publication Part Number | A01620 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates hydrogen, oxygen, nitrogen, helium, and neon in 70 seconds.
- Publication Part Number: A0860
- Created: 31 Oct 2011
- 374 KB
Publication Part Number | A00860 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column module and Agilent 490 Micro GC separates components in natural gas in 55 seconds.
- Publication Part Number: A0878
- Created: 31 Oct 2011
- 423 KB
Publication Part Number | A00878 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC detects oxygen, nitrogen, and methane at 100 ppm in 17 seconds.
- Publication Part Number: A0865
- Created: 31 Oct 2011
- 373 KB
Publication Part Number | A00865 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in four minutes.
- Publication Part Number: A0294
- Created: 31 Oct 2011
- 372 KB
Publication Part Number | A00294 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates six permanent gases in water in four minutes.
- Publication Part Number: A0684
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A00684 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01249
- Created: 31 Oct 2011
- 395 KB
Publication Part Number | A01249 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC and a special column module determines 1-butyl mercaptane (TBM) in natural gas in
- Publication Part Number: A01236
- Created: 31 Oct 2011
- 320 KB
Publication Part Number | A01236 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates permanent gases in propylene in less than five minutes.
- Publication Part Number: A01272
- Created: 31 Oct 2011
- 880 KB
Publication Part Number | A01272 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Molsieve column identifies the oxygen and argon content in a sample of high purity nitrogen in less than two minutes.
- Publication Part Number: A0767
- Created: 31 Oct 2011
- 359 KB
Publication Part Number | A00767 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC detects nitrous oxide in air in 25 seconds.
- Publication Part Number: A0882
- Created: 31 Oct 2011
- 289 KB
Publication Part Number | A00882 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Molsieve 5Å column module and Agilent 490 Micro GC separates oxygen, nitrogen, methane and carbon monoxide in coke gas in 55 seconds.
- Publication Part Number: A0869
- Created: 31 Oct 2011
- 431 KB
Publication Part Number | A00869 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-COx column module and Agilent 490 Micro GC analyzes carbon monoxide and carbon dioxide in 250 seconds.
- Publication Part Number: A0990
- Created: 31 Oct 2011
- 487 KB
Publication Part Number | A00990 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT column separates ammonia and four very volatile amines in 12 minutes.
- Publication Part Number: A0775
- Created: 31 Oct 2011
- 525 KB
Publication Part Number | A00775 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column module and Agilent 490 Micro GC analyzes CFC 113 in air 17 seconds.
- Publication Part Number: A0873
- Created: 31 Oct 2011
- 373 KB
Publication Part Number | A00873 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column identifies trace water in acetone in five minutes.
- Publication Part Number: A0669
- Created: 31 Oct 2011
- 497 KB
Publication Part Number | A00669 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in only 3.5 minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02017
- Created: 31 Oct 2011
- 780 KB
Publication Part Number | A02017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|