Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
The conversion of methanol into ethanol by reaction with hydrogen and carbon monoxide is well known
- Publication Part Number: SI-02484
- Created: 17 Sep 2012
- 175 KB
Publication Part Number | SI-02484 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
HJ
- Publication Part Number: SI-00940
- Created: 05 Dec 2011
- 164 KB
Publication Part Number | SI-00940 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight solvents in five minutes.
- Publication Part Number: A0442
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A00442 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates ten oxygenates in 11 minutes.
- Publication Part Number: A0904
- Created: 31 Oct 2011
- 723 KB
Publication Part Number | A00904 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three C1 to C2 halogenated hydrocarbons in 60 seconds.
- Publication Part Number: A0443
- Created: 31 Oct 2011
- 560 KB
Publication Part Number | A00443 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with Agilent J&W PoraPLOT Q columns of different dimensions analyzes 10 solvents in 20 minutes to demonstrate the effect of column length on separation.
- Publication Part Number: A0667
- Created: 31 Oct 2011
- 699 KB
Publication Part Number | A00667 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six C1 halogenated methane hydrocarbons in six minutes.
- Publication Part Number: A00583
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00583 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 14 halogenated hydrocarbons in a water sample in 15 minutes.
- Publication Part Number: A00071
- Created: 31 Oct 2011
- 516 KB
Publication Part Number | A00071 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 19 solvents in 17 minutes.
- Publication Part Number: A0719
- Created: 31 Oct 2011
- 680 KB
Publication Part Number | A00719 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column analyzes sunflower oils to determine their rancidity.
- Publication Part Number: A0673
- Created: 31 Oct 2011
- 821 KB
Publication Part Number | A00673 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 15 solvents in 18 minutes.
- Publication Part Number: A01282
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A01282 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates six C1 to C5 alcohols in a yeast (Saccharomyces) culture in 25 minutes.
- Publication Part Number: A0355
- Created: 31 Oct 2011
- 626 KB
Publication Part Number | A00355 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates five solvents in 18 minutes.
- Publication Part Number: A01285
- Created: 31 Oct 2011
- 644 KB
Publication Part Number | A01285 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates nine solvents in 18 minutes.
- Publication Part Number: A1286
- Created: 31 Oct 2011
- 803 KB
Publication Part Number | A01286 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Carbowax 400 for Volatiles in Alcohol column separates 10 volatiles in ethanol in seven minutes.
- Publication Part Number: A0432
- Created: 31 Oct 2011
- 644 KB
Publication Part Number | A00432 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with headspace analysis and an Agilent J&W CP-Select 624 CB column separates 18 solvent standards in DMSO in 30 minutes.
- Publication Part Number: A01389
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01389 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates eight solvents in 18 minutes.
- Publication Part Number: A01284
- Created: 31 Oct 2011
- 708 KB
Publication Part Number | A01284 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 16 solvents in 21minutes.
- Publication Part Number: A00502
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00502 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 13 trace C1 to C3 hydrocarbon solvents in drinking water in 11 minutes.
- Publication Part Number: A01423
- Created: 31 Oct 2011
- 878 KB
Publication Part Number | A01423 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 15 solvents in 18 minutes.
- Publication Part Number: A01283
- Created: 31 Oct 2011
- 839 KB
Publication Part Number | A01283 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|