Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Chemical Group
-
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
MMEA and MDEA are used to remove sulfur compounds from hydrocarbons.必威体育登录手机Agilent J&W CP-Volamine is ideal for these highly polar compounds.
- Publication Part Number: A01914
- Created: 01 Oct 2011
- 792 KB
Publication Part Number | A01914 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Volamine column separates polar volatiles such as carbon dioxide, ammonia and water in under two minutes.
- Publication Part Number: A01915
- Created: 01 Oct 2011
- 735 KB
Publication Part Number | A01915 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Volamine column separates VOCs in less than four minutes.
- Publication Part Number: A01913
- Created: 01 Oct 2011
- 698 KB
Publication Part Number | A01913 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of glycolaldehyde in monoethylene glycol using an Agilent J&W CP-Volamine column takes seven minutes.
- Publication Part Number: A01859
- Created: 01 Oct 2011
- 743 KB
Publication Part Number | A01859 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Impurities in monoethylene glycol are detected by GC/MS with an Agilent J&W CP-Volamine column in six minutes.
- Publication Part Number: A01917
- Created: 01 Oct 2011
- 680 KB
Publication Part Number | A01917 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Volamine column separates volatile sulfur compounds in eight minutes.
- Publication Part Number: A01865
- Created: 01 Oct 2011
- 717 KB
Publication Part Number | A01865 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of six chlorinated phenols using an Agilent J&W CP-Volamine column is achieved in 30 minutes.
- Publication Part Number: A01855
- Created: 01 Oct 2011
- 829 KB
Publication Part Number | A01855 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Oxygenated compounds are separated by GC/MS on the amine-deactivated Agilent J&W CP-Volamine capillary column in 13 minutes.
- Publication Part Number: A01916
- Created: 01 Oct 2011
- 990 KB
Publication Part Number | A01916 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of three glycols in water using an Agilent J&W CP-Volamine column is achieved in 18 minutes.
- Publication Part Number: A01854
- Created: 01 Oct 2011
- 771 KB
Publication Part Number | A01854 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|