Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
Fifteen days' exposure to oxygen in GC carrier gas ruptured the filament and affected column bleed, retention time drift, endrin/DDT breakdown, S/N, and EMV.
- Publication Part Number: 5991-4110EN
- Created: 01 Mar 2014
- 266 KB
Publication Part Number | 5991-4110EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Application note for the multi-residue analysis of PAHs, PCBs and OCPs using an Agilent FactorFour VF-35ms Column
- Publication Part Number: SI-2396
- Created: 30 Jan 2014
- 274 KB
Publication Part Number | SI-02396 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Application note for the multi-residue analysis for PAHs, PCBs and OCPs on FactorFour VF-200ms
- Publication Part Number: SI-02467
- Created: 30 Jan 2014
- 348 KB
Publication Part Number | SI-02467 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Multi-residue analysis of PAHs, PCBs and OCPs was performed using GC/MS with Agilent J&W FactorFour VF-Xms column, demonstrating separation
- Publication Part Number: SI-02443
- Created: 09 Aug 2013
- 302 KB
Publication Part Number | SI-02443 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Multi-residue analysis of PAHs, PCBs and OCPs in environmental samples using a GC-MS with a FactorFour VF-5ms column and quadrupole MS.
- Publication Part Number: SI-2364
- Created: 26 Sep 2012
- 167 KB
Publication Part Number | SI-02364 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 19 CB for Pesticides column separates 22 pesticides in 18 minutes.
- Publication Part Number: A01251
- Created: 31 Oct 2011
- 762 KB
Publication Part Number | A01251 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 16 organochlorine pesticides according to EPA625 in 27 minutes.
- Publication Part Number: A02092
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A02092 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|