Refine Results
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 6410 Triple Quadrupole Mass spectrometer (1)
Instrument
- Language
-
Language
Applied Filters
Steroidal saponins in two species of yams are characterized by high resolution accurate mass measurement MS/MS and the MS is used to differentiate the two species.
- Publication Part Number: 5991-4540EN
- Created: 17 Dec 2014
- 600 KB
Publication Part Number | 5991-4540EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
This note describes the 1290 Infinity 2D-LC Solution in combination with the 6530 Accurate-Mass Q-TOF LC/MS for the separation,detection and accurate mass measurement.
- Publication Part Number: 5991-4733EN
- Created: 15 June 2014
- 905 KB
Publication Part Number | 5991-4733EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Demonstration of the Agilent 1290 Infinity 2D-LC Solution to resolve the hydrophilic phenols in virgin olive oils and investigation of differences between olive oils.
- Publication Part Number: 5991-4515EN
- Created: 01 May 2014
- 3 MB
Publication Part Number | 5991-4515EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Two sample preparation techniques were explored for the analysis of adulterants in erectile dysfunction dietary supplements using LC/MS/MS.
- Publication Part Number: 5991-3638EN
- Created: 03 Feb 2014
- 241 KB
Publication Part Number | 5991-3638EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Four low calorie sweeteners were analyzed by LC/MS.The method was fast, easy, and cheap providing routine analysis with high throughput at a low cost.
- Publication Part Number: 5991-2860EN
- Created: 31 July 2013
- 618 KB
Publication Part Number | 5991-2860EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column identifies 12 aromas in a lily plant in 40 minutes.
- Publication Part Number: A1010
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A01010 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column identifies 14 aromas in a rose plant in 40 minutes.
- Publication Part Number: A1011
- Created: 31 Oct 2011
- 567 KB
Publication Part Number | A01011 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC analysis of ten sugars as hexa acetates is accomplished using an Agilent J&W VF-200ms column in 36 minutes.
- Publication Part Number: A02237
- Created: 31 Oct 2011
- 911 KB
Publication Part Number | A02237 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机HPLC with DAD and MS using an Agilent Polaris C18-A column separates two imidazoles in a caramel coloring in less than two minutes.
- Publication Part Number: A01938
- Created: 01 Oct 2011
- 760 KB
Publication Part Number | A01938 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Analysis of acrylamide in chocolate, chips, waffles, coffee and cacao powder using GC/MS with Agilent J&W VF-5ms after liquid/liquid extraction with Agilent Chem Elut.
- Publication Part Number: A02437
- Created: 11 May 2010
- 3 MB
Publication Part Number | A02437 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
茶葉、化妝品和草藥中使用到三類洋甘菊花,本應用中使用了氣相色譜/質譜(GC/MS)和 Mass Profiler Professional 軟件對這三類洋甘菊花進行分類。
- Publication Part Number: 5991-3969CHCN
- Created: 20 June 2014
- 3 MB
Publication Part Number | 5991-3969EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机使用便攜式Agilent 5975T 液質聯用係統鑒定常見休閑食品中的香精香料過敏原
- Publication Part Number: 5991-1438CHCN
- Created: 09 Nov 2012
- 300 KB
Publication Part Number | 5991-1438EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|