Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
Analysis of multiple semi-volatile organic compounds by USEPA method 8270D is challenging.It was performed by GC/MS with FactorFour VF-5ms column and quadrupole MS, giving 7
- Publication Part Number: SI-2365
- Created: 01 Aug 2013
- 253 KB
Publication Part Number | SI-02365 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
Publication Part Number | 5991-2153EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
A fast responding mobile solution from sampler to detector with small size and low power consumption is highly desirable for on-site air pollutant analysis.
- Publication Part Number: 5991-1500EN
- Created: 09 Nov 2012
- 688 KB
Publication Part Number | 5991-1500EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Russian (Russia) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机GC/MS using an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 25 nitroaromatic standards in 37 minutes.
- Publication Part Number: A01225
- Created: 31 Oct 2011
- 507 KB
Publication Part Number | A01225 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 13base neutrals according to EPA8270 in 20 minutes.
- Publication Part Number: A2090
- Created: 31 Oct 2011
- 503 KB
Publication Part Number | A02090 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC/MS analysis of eight nitroaromatics and cyclic ketones according to EPA 8090, with an Agilent J&W VF-200ms column, is achieved in less than 20 minutes.
- Publication Part Number: A02097
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A02097 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Using GC/MS, an Agilent J&W VF-200ms column separates 14base neutrals in 20 minutes.
- Publication Part Number: A02089
- Created: 31 Oct 2011
- 484 KB
Publication Part Number | A02089 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
- Publication Part Number: 5990-6322CHCN
- Created: 15 Sep 2010
- 279 KB
Publication Part Number | 5990-6322EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|