Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 40 polychlorinated biphenyls in the liver of an oyster catcher in 56 minutes.
- Publication Part Number: A0337
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00337 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select for PCB column separates seven polychlorinated biphenyls in cod liver oil in 12 minutes.
- Publication Part Number: A01543
- Created: 31 Oct 2011
- 550 KB
Publication Part Number | A01543 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 for PCB column resolves two polycyclic aromatic hydrocarbons in transformer oil in 50 minutes.
- Publication Part Number: A01101
- Created: 31 Oct 2011
- 426 KB
Publication Part Number | A01101 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Sil 5/C18 for PCB column separates seven polychlorinated biphenyl contaminants in a sample of transformer oil in 46 minutes.
- Publication Part Number: A01104
- Created: 31 Oct 2011
- 475 KB
Publication Part Number | A01104 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent CP-Sil 88 column separates over 50 chlorophenyls in 72 minutes.
- Publication Part Number: A00584
- Created: 31 Oct 2011
- 683 KB
Publication Part Number | A00584 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5/C18 for PCB column resolves five polychlorinated biphenyl contaminants in transformer oil in 46 minutes.
- Publication Part Number: A01102
- Created: 31 Oct 2011
- 457 KB
Publication Part Number | A01102 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|