必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机B100 biodiesel was assayed for free and total glycerol content to EN 14105 with an Agilent Multi-Mode Inlet and UltiMetal Agilent J&W Select Biodiesel for Glycerides.
- Publication Part Number: 5991-3224EN
- Created: 23 Sep 2013
- 122 KB
Publication Part Number | 5991-3224EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
必威体育登录手机Isobaric ppb PAHs are separated in cocoa and peanut by SIM GC/MS with a short Agilent J&W Select PAH GC column and Agilent Bond Elut SPE, with co-extracted triglycerides.
- Publication Part Number: 5991-2299EN
- Created: 07 May 2013
- 651 KB
Publication Part Number | 5991-2299EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 24 CB column resolves 22 methylated chlorophenoxycarboxylic acids in 35 minutes.
- Publication Part Number: A1090
- Created: 31 Oct 2011
- 649 KB
Publication Part Number | A01090 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 88 column separates 16 fatty acid methyl esters of conjugated linoleic acids in soya bean oil in 50 minutes.
- Publication Part Number: A01649
- Created: 31 Oct 2011
- 752 KB
Publication Part Number | A01649 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00271 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 components in a sample of crude oil in 50 minutes.
- Publication Part Number: A00096
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A00096 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of 16 polyaromatic hydrocarbons according to EPA 610 is achieved in less than 23 minutes using Agilent J&W VF-5ms EZ-Guard columns.
- Publication Part Number: A02209
- Created: 31 Oct 2011
- 940 KB
Publication Part Number | A02209 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of 25 pesticides using splitless injection on a 0.15 mm id Agilent J&W CP-Sil 13 CB column.
- Publication Part Number: A02239
- Created: 31 Oct 2011
- 633 KB
Publication Part Number | A02239 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB Low Bleed/MS column separates 29 C8 to C17aromatic hydrocarbons in 30 minutes.
- Publication Part Number: A01264
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01264 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Before GC with Agilent J&W CP-Sil 88 for FAME, C20:3 and C20:4 isomers are isolated by HPLC and fractionation to separate fatty acids by their double-bond positions.
- Publication Part Number: A01530
- Created: 31 Oct 2011
- 516 KB
Publication Part Number | A01530 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机High resolution analysis of 32 heavier alcohols as TMS derivatives in marine sediments is achieved using an Agilent J&W VF-5ms column.
- Publication Part Number: A01995
- Created: 31 Oct 2011
- 866 KB
Publication Part Number | A01995 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates three esters in a thinner for polyurethane paint in 15 minutes.
- Publication Part Number: A0487
- Created: 31 Oct 2011
- 475 KB
Publication Part Number | A00487 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column identifies four diterpenes in an Italian espresso coffee in 30 minutes.
- Publication Part Number: A0988
- Created: 31 Oct 2011
- 566 KB
Publication Part Number | A00988 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates chemical warfare agents in 24 minutes.
- Publication Part Number: A01617
- Created: 31 Oct 2011
- 489 KB
Publication Part Number | A01617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five anabolic steroids in urine in 20 minutes.
- Publication Part Number: A00058
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00058 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with headspace analysis and Agilent J&W CP-Select 624 CB separates eight residual solvents in 20 minutes according to European Pharmacopoeia and USP methods.
- Publication Part Number: A01265
- Created: 31 Oct 2011
- 512 KB
Publication Part Number | A01265 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-FFAP column separates nine C2 to C10 free fatty acids in a wine distillate in nine minutes.
- Publication Part Number: A0364
- Created: 31 Oct 2011
- 781 KB
Publication Part Number | A00364 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates ten phthalate esters in a plastic toy in 30 minutes.
- Publication Part Number: A01462
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01462 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using splitless injection with an Agilent J&W PoraBOND Q column separates 17 polar solvents in a water sample in 18 minutes.
- Publication Part Number: A01428
- Created: 31 Oct 2011
- 715 KB
Publication Part Number | A01428 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|