Refine Results
- 必威体育赛事投注
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机An Agilent 7890B GC system configured with three detectors was used for the analysis of pesticides in water.
- Publication Part Number: 5991-2787EN
- Created: 05 Aug 2013
- 1 MB
Publication Part Number | 5991-2787EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Agilent's new deactivation of the 6% cyanopropyl dimethylpolysiloxane (624) phase significantly improves acid performance and maintains very good performance.
- Publication Part Number: 5991-0845EN
- Created: 31 July 2012
- 2 MB
Publication Part Number | 5991-0845EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (United States) | Complete (PDF) |
---|
HJ
- Publication Part Number: SI-00939
- Created: 05 Dec 2011
- 180 KB
Publication Part Number | SI-00939 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates nine C7 to C9 aromatic hydrocarbon impurities in o-xylene in 16 minutes.
- Publication Part Number: A0418
- Created: 31 Oct 2011
- 723 KB
Publication Part Number | A00418 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates 16 solvents in 35 minutes.
- Publication Part Number: A0109
- Created: 31 Oct 2011
- 621 KB
Publication Part Number | A00109 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent J&W VF-200ms column provides unique separation of VOCs listed in US EPA Methods 524 and 8260, and is the best column to separate xylene isomers.
- Publication Part Number: A02215
- Created: 31 Oct 2011
- 722 KB
Publication Part Number | A02215 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates several aromatics, and butanol, in 20 minutes.
- Publication Part Number: A00076
- Created: 31 Oct 2011
- 461 KB
Publication Part Number | A00076 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机An Agilent J&W CP-Wax 52 CB column separates 22 solvents by gas chromatography in 40 minutes.
- Publication Part Number: A01952
- Created: 31 Oct 2011
- 682 KB
Publication Part Number | A01952 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 alkanes and C5 to C9 aromatics in 50 minutes.
- Publication Part Number: A00020
- Created: 31 Oct 2011
- 640 KB
Publication Part Number | A00020 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using Agilent J&W PoraPLOT Q and PoraPLOT Q-HT columns separate 22 C1to C8 hydrocarbons and C1 to C2 halogenated hydrocarbons in 30 minutes.
- Publication Part Number: A01268
- Created: 31 Oct 2011
- 711 KB
Publication Part Number | A01268 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates 35 C1 - C7 oxygenated compounds in a sample of botanical air in 42 minutes.
- Publication Part Number: A01615
- Created: 31 Oct 2011
- 793 KB
Publication Part Number | A01615 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates ten C6 to C8 aromatic hydrocarbons in 12 minutes.
- Publication Part Number: A0352
- Created: 31 Oct 2011
- 741 KB
Publication Part Number | A00352 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Si 5 CB column separates 35 solvents and contaminants in a sample of industrial waste water in 18 minutes.
- Publication Part Number: A01451
- Created: 31 Oct 2011
- 833 KB
Publication Part Number | A01451 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 11 C5 to C11 impurities in dicyclopentadiene in 40 minutes.
- Publication Part Number: A0152
- Created: 31 Oct 2011
- 638 KB
Publication Part Number | A00152 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C9 hydrocarbons in air in 60 minutes.
- Publication Part Number: A00056
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00056 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates 13 C8 to C12 alkanes and C6 to C10 aromatics in 20 minutes.
- Publication Part Number: A00032
- Created: 31 Oct 2011
- 437 KB
Publication Part Number | A00032 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 31 C6 to C13 polycyclic aromatic hydrocarbons in 51 minutes.
- Publication Part Number: A0652
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00652 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|