Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
-
- Instrument
-
必威体育登录手机Agilent 7683B Automatic Liquid sampler (1)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
note cites and is supported by a VOC kit that contains the necessary parts to implement this VOC solution set.
- Publication Part Number: 5991-0029EN
- Created: 23 June 2015
- 4 MB
Publication Part Number | 5991-0029EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Application note describes innovative method for the confirmation of fire accelerants using the Agilent Capillary Trap Sampler (CTS).
- Publication Part Number: 5991-3439EN
- Created: 12 Dec 2013
- 250 KB
Publication Part Number | 5991-3439EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
Following the European Standard EN 71 part 11, an economical solution for the determination of VOCs was developed on a 7820A GC with a 5977E GC/MSD Sys configured to a 7667A
- Publication Part Number: 5991-3604EN
- Created: 15 Nov 2013
- 133 KB
Publication Part Number | 5991-3604EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Volatile (vapor-phase) organic air toxics ‘Hazardous Air Pollutants' (HAPS) in many industrial & urban environments as a measure of air quality.
- Publication Part Number: 5991-2826EN
- Created: 26 July 2013
- 830 KB
Publication Part Number | 5991-2826EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
Japanese (Japan) | Complete (PDF) |
---|
A fast responding mobile solution from sampler to detector with small size and low power consumption is highly desirable for on-site air pollutant analysis.
- Publication Part Number: 5991-1500EN
- Created: 09 Nov 2012
- 688 KB
Publication Part Number | 5991-1500EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
Russian (Russia) | Complete (PDF) |
---|---|
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机Gas chromatography using an Agilent J&W CP-TCEP for Alcohols in Gasoline column separates 15 aromatics and alcohol from gasoline in 28 minutes.
- Publication Part Number: A00031
- Created: 31 Oct 2011
- 724 KB
Publication Part Number | A00031 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 C1 to C10 aromatic hydrocarbons in 23 minutes.
- Publication Part Number: A0351
- Created: 31 Oct 2011
- 911 KB
Publication Part Number | A00351 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Xylenes column separates 11 aromatic hydrocarbons in 34 minutes.
- Publication Part Number: A0987
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A00987 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC/MS with TCT injection and an Agilent J&W CP-Sil 5 CB column identifies 39 trace components in air in 84 minutes.
- Publication Part Number: A0265
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00265 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Fast GC/MS with an Agilent J&W CP-Select 624 CB column separates 60 solvents in 16 minutes according to EPA 524.2.
- Publication Part Number: A01255
- Created: 31 Oct 2011
- 764 KB
Publication Part Number | A01255 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 16 C6 to C13 aromatic hydrocarbons in 30 minutes.
- Publication Part Number: A0252
- Created: 31 Oct 2011
- 498 KB
Publication Part Number | A00252 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates over 165 C4 to C12 hydrocarbons in 130 minutes.
- Publication Part Number: A00602
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00602 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 C1 to C9 hydrocarbons and C6 to C9 aromatics in 40 minutes.
- Publication Part Number: A0604
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A00604 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC/MS with an Agilent J&W CP-Select 624 CB column separates 53 volatile organic compounds according to EPA 524 in 30 minutes.
- Publication Part Number: A01450
- Created: 31 Oct 2011
- 954 KB
Publication Part Number | A01450 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates 111 C4 to C11 hydrocarbons in 49 minutes.
- Publication Part Number: A0903
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00903 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 31 C6 to C13 polycyclic aromatic hydrocarbons in 51 minutes.
- Publication Part Number: A0652
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00652 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 81 C1 to C7 hydrocarbons in car exhaust gas in 33 minutes.
- Publication Part Number: A0895
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00895 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 57 halogenated hydrocarbon purgeables according to EPA 524.2 in 54 minutes.
- Publication Part Number: A0616
- Created: 31 Oct 2011
- 895 KB
Publication Part Number | A00616 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 71 halogenated hydrocarbons in water according to EPA 524.5, in 60 minutes.
- Publication Part Number: A1017
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01017 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 42 organic solvents in 35 minutes.
- Publication Part Number: A0493
- Created: 31 Oct 2011
- 671 KB
Publication Part Number | A00493 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|