Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography and an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separate six alcohols and glycols in a water sample in seven minutes.
- Publication Part Number: A01330
- Created: 30 Nov 2015
- 860 KB
Publication Part Number | A01330 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Optimizing Analytical Performance and Extending the Application Range of Thermal Desorption for Monitoring Air Indoors and Inside Vehicle Cabins
- Publication Part Number: 5991-2827EN
- Created: 26 July 2013
- 2 MB
Publication Part Number | 5991-2827EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 glycols in ten minutes.
- Publication Part Number: A0154
- Created: 31 Oct 2011
- 629 KB
Publication Part Number | A00154 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC separation of ten glycols using an Agilent J&W CP-Wax 52 CB column with FID is achieved in under 40 minutes.
- Publication Part Number: A01954
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01954 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column uses on line analysis to identify diethylene glycol in monoethylene glycol in three minutes.
- Publication Part Number: A0657
- Created: 31 Oct 2011
- 449 KB
Publication Part Number | A00657 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates seven glycols and glycerols in eight minutes.
- Publication Part Number: A0770
- Created: 31 Oct 2011
- 522 KB
Publication Part Number | A00770 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates mono-, di-, tri-, and tetraethylene glycols in 15 minutes.
- Publication Part Number: A0467
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00467 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates four glycols (ppm level) in water in 13 minutes.
- Publication Part Number: A0712
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00712 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates two polyalcohols in seven minutes.
- Publication Part Number: A0694
- Created: 31 Oct 2011
- 448 KB
Publication Part Number | A00694 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates impurities in propylene glycol in 30 minutes, according to DAB 1995/USP 23.
- Publication Part Number: A01385
- Created: 31 Oct 2011
- 562 KB
Publication Part Number | A01385 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 13 glycols and diols in less than 20 minutes.
- Publication Part Number: A01417
- Created: 31 Oct 2011
- 524 KB
Publication Part Number | A01417 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS separation of three glycols in water using an Agilent J&W CP-Volamine column is achieved in 18 minutes.
- Publication Part Number: A01854
- Created: 01 Oct 2011
- 771 KB
Publication Part Number | A01854 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Application note for the analysis of volatile organic compounds in waterborne interior architectural paints
- Publication Part Number: 5990-6784EN
- Created: 09 Nov 2010
- 412 KB
Publication Part Number | 5990-6784EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|