必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates carbonyl sulfide and ethylene in seven minutes.
- Publication Part Number: A01260
- Created: 31 Oct 2011
- 486 KB
Publication Part Number | A01260 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates methyl chloride and dimethyl ether impurities in methanol in less than eight minutes.
- Publication Part Number: A01589
- Created: 31 Oct 2011
- 392 KB
Publication Part Number | A01589 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC detects CFC 14 (CF4) in air in nine seconds.
- Publication Part Number: A0883
- Created: 31 Oct 2011
- 304 KB
Publication Part Number | A00883 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six gases in water solvents in five minutes.
- Publication Part Number: A0439
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00439 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column separates hydrochloric acid and water in less than seven minutes, withstanding repeated injections of HCl very well.
- Publication Part Number: A01601
- Created: 31 Oct 2011
- 325 KB
Publication Part Number | A01601 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module detects carbon dioxide in air in nine seconds.
- Publication Part Number: A0885
- Created: 31 Oct 2011
- 300 KB
Publication Part Number | A00885 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Volamine column elutes volatile amines as symmetrical peaks, as well as low levels of alcohols, air and water.
- Publication Part Number: A01586
- Created: 31 Oct 2011
- 679 KB
Publication Part Number | A01586 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS with an Agilent J&W VF-Xms column separates 11 solvents in six minutes, including highly polar compounds such as methanol and water at low levels.
- Publication Part Number: A01964
- Created: 31 Oct 2011
- 687 KB
Publication Part Number | A01964 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates carbon monoxide, carbon dioxide and other gases in air in five minutes.
- Publication Part Number: A0494
- Created: 31 Oct 2011
- 510 KB
Publication Part Number | A00494 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates six permanent gases in water in four minutes.
- Publication Part Number: A0684
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A00684 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机On-site air is monitored with Agilent 490 Micro GC and Agilent J&W CP-Sil 8 CB.Target components are aromatics, which can be measured within 150 s down to ppm.
- Publication Part Number: A01622
- Created: 31 Oct 2011
- 500 KB
Publication Part Number | A01622 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in less than 20 minutes using Agilent PLOT columns in tandem, with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02031
- Created: 31 Oct 2011
- 616 KB
Publication Part Number | A02031 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three components in an air sample in two minutes.
- Publication Part Number: A0282
- Created: 31 Oct 2011
- 354 KB
Publication Part Number | A00282 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates acetylene, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0892
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A00892 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND U column analyzes C3 oxygenated hydrocarbons in less than ten minutes.
- Publication Part Number: A01562
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A01562 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of refrigerant impurities in CFC-22 is achieved in less than 50 seconds using an Agilent J&W PoraPLOT U column and Agilent 490 Micro GC.
- Publication Part Number: A01959
- Created: 31 Oct 2011
- 560 KB
Publication Part Number | A01959 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten propellants and solvents in aerosol containers in six minutes.
- Publication Part Number: A0333
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00333 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four gases in air in 22 seconds.
- Publication Part Number: A00887
- Created: 31 Oct 2011
- 530 KB
Publication Part Number | A00887 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates water in nine solvents in less than seven minutes.
- Publication Part Number: A00582
- Created: 31 Oct 2011
- 623 KB
Publication Part Number | A00582 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates five permanent gases in about five minutes.
- Publication Part Number: A00036
- Created: 31 Oct 2011
- 412 KB
Publication Part Number | A00036 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|