Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Detection Technique
- Injection Technique
- Instrument
- Method
-
- Language
-
Language
Applied Filters
Analysis of multiple semi-volatile organic compounds by USEPA method 8270D is challenging.It was performed by GC/MS with FactorFour VF-5ms column and quadrupole MS, giving 7
- Publication Part Number: SI-2365
- Created: 01 Aug 2013
- 253 KB
Publication Part Number | SI-02365 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机This application note describes the USEPA Method 8270 with Agilent 5977A GC/MSD systems for analysis of semi-volatile organic compounds over a wide concentration range.
- Publication Part Number: 5991-2153EN
- Created: 11 Apr 2013
- 3 MB
Publication Part Number | 5991-2153EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机The Agilent J&W VF-17ms GC column separates 14 base neutrals in 28 minutes.
- Publication Part Number: A02275
- Created: 31 Oct 2011
- 846 KB
Publication Part Number | A02275 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 82 pollutants according to EPA 625 in 65 minutes.
- Publication Part Number: A0789
- Created: 31 Oct 2011
- 801 KB
Publication Part Number | A00789 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 12 phthalate esters according to EPA 8060 in 22 minutes.
- Publication Part Number: A0795
- Created: 31 Oct 2011
- 438 KB
Publication Part Number | A00795 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten phthalate esters and alcohols in 13 minutes.
- Publication Part Number: A00019
- Created: 31 Oct 2011
- 411 KB
Publication Part Number | A00019 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of 14 base neutrals with an Agilent J&W VF-200ms column achieves a separation in 28 minutes.
- Publication Part Number: A02200
- Created: 31 Oct 2011
- 617 KB
Publication Part Number | A02200 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates ten phthalate esters in a plastic toy in 30 minutes.
- Publication Part Number: A01462
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01462 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 12 adipate and phthalate esters used as plasticizers in 24 minutes.
- Publication Part Number: A0617
- Created: 31 Oct 2011
- 649 KB
Publication Part Number | A00617 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS of 16 phthalate esters is achieved in 33 minutes using an Agilent J&W CP-Sil 8 CB column.
- Publication Part Number: A01657
- Created: 31 Oct 2011
- 675 KB
Publication Part Number | A01657 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates six phthalate esters according to EPA 606 in 50 minutes.
- Publication Part Number: A0784
- Created: 31 Oct 2011
- 479 KB
Publication Part Number | A00784 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column identifies seven impurities in dioctyl phthalate (PVC plasticizer) in nine minutes.
- Publication Part Number: A0473
- Created: 31 Oct 2011
- 652 KB
Publication Part Number | A00473 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 41 organic water pollutants according to EPA 525 in 50 minutes.
- Publication Part Number: A0781
- Created: 31 Oct 2011
- 797 KB
Publication Part Number | A00781 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W VF-Xms column separates 12 phthalate esters in 40 minutes using the EPA 8060 method.
- Publication Part Number: A01966
- Created: 31 Oct 2011
- 864 KB
Publication Part Number | A01966 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 120 semivolatiles according to EPA 8270 in 94 minutes.
- Publication Part Number: A0805
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A00805 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Analysis of 14 base neutrals by gas chromatography using an Agilent J&W VF-1301ms column in less than 40 minutes.
- Publication Part Number: A02414
- Created: 11 May 2010
- 720 KB
Publication Part Number | A02414 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent J&W VF-1701ms columns separate 14 base neutrals in 37 minutes.
- Publication Part Number: A02386
- Created: 11 May 2010
- 712 KB
Publication Part Number | A02386 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|