Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separate 58 organophosphorus pesticides in 26 minutes.
- Publication Part Number: A01348
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A01348 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five underivatized drugs of abuse in an ecstasy tablet in 15 minutes.
- Publication Part Number: A01392
- Created: 31 Oct 2011
- 540 KB
Publication Part Number | A01392 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates five underivatized drugs of abuse in a ‘brown powder' sample in 15 minutes.
- Publication Part Number: A01391
- Created: 31 Oct 2011
- 581 KB
Publication Part Number | A01391 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 25 organophosphorus pesticides according to EPA 8140 and 8141 in 31 minutes.
- Publication Part Number: A0615
- Created: 31 Oct 2011
- 867 KB
Publication Part Number | A00615 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 8 CB column separates 18 underivatized drugs of abuse in a standard mixture in 15 minutes.
- Publication Part Number: A01390
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A01390 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 17 organophosphorus pesticides with thioether groups in 24 minutes.
- Publication Part Number: A0614
- Created: 31 Oct 2011
- 728 KB
Publication Part Number | A00614 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 11 triazine herbicides in 15 minutes.
- Publication Part Number: A0613
- Created: 31 Oct 2011
- 693 KB
Publication Part Number | A00613 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 39 fungicides in 30 minutes.
- Publication Part Number: A0610
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|