Application note for the analysis of Fluid Cat Cracker Feed using a VF-5ht UltiMetal Column
- Publication Part Number: SI-01130
- Created: 29 Jan 2014
- 195 KB
Publication Part Number | SI-01130 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
The VF-5ht UltiMetal column provides an unbreakable metal column with excellent inertness similar to fused silica tubing.
- Publication Part Number: SI-01317
- Created: 17 Sep 2012
- 195 KB
Publication Part Number | SI-01317 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
JK
- Publication Part Number: SI-02105
- Created: 05 Dec 2011
- 467 KB
Publication Part Number | SI-02105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机An oncolumn method is used for soil analysis by GC, allowing C10 to C40 to be determined in less than 5 minutes with Agilent J&W Select Mineral Oil.
- Publication Part Number: A01976
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A01976 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist UltiMetal column analyzes a sample of mineral oil in 50 minutes.
- Publication Part Number: A01325
- Created: 31 Oct 2011
- 599 KB
Publication Part Number | A01325 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-SimDist UltiMetal column separate hydrocarbons according to IP PM-CX/98.
- Publication Part Number: A01335
- Created: 31 Oct 2011
- 956 KB
Publication Part Number | A01335 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机With Agilent J&W VF-5ht, on-column injection of diesel minimizes discrimination effects that can occur in split, splitless and PTV type injection systems.
- Publication Part Number: A02367
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02367 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|