Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Detection Technique
-
- Instrument
-
必威体育登录手机Agilent 7000 Triple Quadrupole GC/MS (2)
Instrument
- Method
-
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column separates 11 aromatics in 15 minutes.
- Publication Part Number: A0111
- Created: 31 Oct 2011
- 592 KB
Publication Part Number | A00111 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 11 triazine herbicides in 15 minutes.
- Publication Part Number: A0613
- Created: 31 Oct 2011
- 693 KB
Publication Part Number | A00613 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent CP-SimDist UltiMetal column separates 11 components in a petroleum wax in 95 minutes.
- Publication Part Number: A0774
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00774 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 11 C4 to C8 alcohols in 36 minutes.
- Publication Part Number: A01106
- Created: 31 Oct 2011
- 548 KB
Publication Part Number | A01106 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 24 CB column separates 19 pesticides in 35 minutes.
- Publication Part Number: A1004
- Created: 31 Oct 2011
- 806 KB
Publication Part Number | A01004 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast analysis of diesel-contaminated samples is achieved by GC with the Agilent J&W Select Mineral Oil column.
- Publication Part Number: A02047
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02047 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates six C50 to C56 triglycerides in Robusta coffee oil in 18 minutes.
- Publication Part Number: A0239
- Created: 31 Oct 2011
- 369 KB
Publication Part Number | A00239 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 19 CB column separates 12 hydroxylated bile acids and cholesterol in 20 minutes.
- Publication Part Number: A0051
- Created: 31 Oct 2011
- 600 KB
Publication Part Number | A00051 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SimDist CB column separates 11 components of mineral oil in a soil sample in less than 15 minutes.
- Publication Part Number: A01105
- Created: 31 Oct 2011
- 505 KB
Publication Part Number | A01105 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separates four glycols in 15 minutes.
- Publication Part Number: A0161
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00161 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separate 58 organophosphorus pesticides in 26 minutes.
- Publication Part Number: A01348
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A01348 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates desmethyldiazepam and donazepam in 35 minutes.
- Publication Part Number: A0114
- Created: 31 Oct 2011
- 417 KB
Publication Part Number | A00114 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the determination of Polychlorinated Dibenzo-p-dioxins and Polychlorinated Dibenzofurans (PCDF) in Foodstuffs and Animal Feed
- Publication Part Number: 5990-6594EN
- Created: 15 Nov 2010
- 944 KB
Publication Part Number | 5990-6594EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机With Agilent J&W VF-5ht, on-column injection of diesel minimizes discrimination effects that can occur in split, splitless and PTV type injection systems.
- Publication Part Number: A02367
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02367 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Analysis of biodiesel (fatty acid methyl esters) using Agilent J&W VF-5ht with very low bleed at 380 oC
- Publication Part Number: A02347
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02347 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent 7696A ワークベンチを用いた複雑なマルチステップサンプル前処理の自動化
- Publication Part Number: 5990-7525JAJP
- Created: 04 July 2014
- 399 KB
Publication Part Number | 5990-7525EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|