必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separate six alcohols and glycols in a water sample in seven minutes.
- Publication Part Number: A01330
- Created: 30 Nov 2015
- 860 KB
Publication Part Number | A01330 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column quantifies the anti-convulsant valproic acid in serum in five minutes.
- Publication Part Number: A00446
- Created: 25 Aug 2015
- 345 KB
Publication Part Number | A00446 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates alcohols in blood/plasma in three minutes.
- Publication Part Number: A01323
- Created: 25 Aug 2015
- 392 KB
Publication Part Number | A01323 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 14 drugs from emergency toxicology plasma extracts in eight minutes.
- Publication Part Number: A0321
- Created: 19 May 2015
- 2 MB
Publication Part Number | A00321 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Application note for the separation of four Anti Slip Agents
- Publication Part Number: SI-02065
- Created: 29 Jan 2014
- 263 KB
Publication Part Number | SI-02065 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column separates trace oxygenates in propylene in less than nine minutes.
- Publication Part Number: A01360
- Created: 31 Oct 2013
- 515 KB
Publication Part Number | A01360 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates seven C3 to C9 volatile alcohols in 12 minutes.
- Publication Part Number: A0176
- Created: 31 Oct 2011
- 542 KB
Publication Part Number | A00176 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q-HT column separates 18 solvents in 50 minutes.
- Publication Part Number: A01256
- Created: 31 Oct 2011
- 638 KB
Publication Part Number | A01256 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Analyze trace halogenated pesticides with Agilent J&W VF-5ms and oncolumn injection to avoid discrimination, adsorption, or decomposition in hot injection ports.
- Publication Part Number: A02254
- Created: 31 Oct 2011
- 674 KB
Publication Part Number | A02254 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of C1 to C4 hydrocarbons is achieved in 15 minutes using the Agilent J&W Select Al2O3 MAPD.
- Publication Part Number: A02042
- Created: 31 Oct 2011
- 990 KB
Publication Part Number | A02042 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates five C5 to C7 cyclic alcohols in eight minutes.
- Publication Part Number: A0177
- Created: 31 Oct 2011
- 480 KB
Publication Part Number | A00177 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates 27 C1 to C7 oxygenated compounds in a hydrocarbon matrix in 42 minutes.
- Publication Part Number: A01614
- Created: 31 Oct 2011
- 782 KB
Publication Part Number | A01614 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Selectivity of the Agilent J&W Select Al2O3 MAPD column is very good for separating impurities in 1,3 butadiene by GC.
- Publication Part Number: A02043
- Created: 31 Oct 2011
- 740 KB
Publication Part Number | A02043 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2SO3/Na2SO4 column separates seven chlorinated fluorocarbons in 20 minutes.
- Publication Part Number: A01447
- Created: 31 Oct 2011
- 631 KB
Publication Part Number | A01447 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 11C1 to C6 volatile halogenated hydrocarbons in nine minutes.
- Publication Part Number: A00016
- Created: 31 Oct 2011
- 441 KB
Publication Part Number | A00016 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column analyzes carbon dioxide and carbon monoxide in hydrocarbon streams in six minutes.
- Publication Part Number: A01431
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A01431 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates permanent gases in propylene in less than five minutes.
- Publication Part Number: A01272
- Created: 31 Oct 2011
- 880 KB
Publication Part Number | A01272 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W VF-23ms column separates eight alditol acetates in nine minutes.
- Publication Part Number: A01968
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A01968 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|