Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using Agilent J&W PoraPLOT Q and PoraPLOT Q-HT columns separate 22 C1to C8 hydrocarbons and C1 to C2 halogenated hydrocarbons in 30 minutes.
- Publication Part Number: A01268
- Created: 31 Oct 2011
- 711 KB
Publication Part Number | A01268 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates volatile halogenated hydrocarbons in a hydrocarbon/water mixture in less than four minutes.
- Publication Part Number: A01324
- Created: 31 Oct 2011
- 538 KB
Publication Part Number | A01324 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 57 halogenated hydrocarbon purgeables according to EPA 524.2 in 54 minutes.
- Publication Part Number: A0616
- Created: 31 Oct 2011
- 895 KB
Publication Part Number | A00616 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column analyzes ethylene oxide spiked with light hydrocarbons, vinyl chloride, and acetaldehyde in 15 minutes.
- Publication Part Number: A0674
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00674 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates five C1 to C3 hydrocarbons and vinyl chloride in air in 14 minutes.
- Publication Part Number: A00580
- Created: 31 Oct 2011
- 555 KB
Publication Part Number | A00580 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates six C1 to C3 hydrocarbons and vinyl chloride in 14 minutes.
- Publication Part Number: A00578
- Created: 31 Oct 2011
- 513 KB
Publication Part Number | A00578 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast analysis of chlorinated hydrocarbons in 60 s is achieved using a short, 0.53 mm id Agilent J&W CP-Silica PLOT column and micro-volume direct injection.
- Publication Part Number: A01920
- Created: 01 Oct 2011
- 778 KB
Publication Part Number | A01920 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC/MS analysis of impurities (halogenated and carbon dioxide) in ethylene is achieved in seven minutes with an Agilent J&W CarboBOND column.
- Publication Part Number: A01923
- Created: 01 Oct 2011
- 686 KB
Publication Part Number | A01923 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机An Agilent J&W CP-Select 624 column and gas chromatography separates 38 volatile organic compounds in water using PID and ELCD detectors.
- Publication Part Number: A01847
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01847 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with the Agilent J&W PoraPLOT Q separates nine impurities in vinylchloride in 23 minutes.
- Publication Part Number: A01902
- Created: 01 Oct 2011
- 1 MB
Publication Part Number | A01902 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|