Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
-
- Injection Technique
- Language
-
Language
Applied Filters
必威体育登录手机GC separation of 37 oxygenated compounds on a highly selective Agilent J&W Lowox multilayer column is achieved in 45 minutes.
- Publication Part Number: A02251
- Created: 31 Oct 2011
- 874 KB
Publication Part Number | A02251 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates five C6 to C9 aromatic hydrocarbons in seven minutes.
- Publication Part Number: A0198
- Created: 31 Oct 2011
- 464 KB
Publication Part Number | A00198 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten C1 to C10 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A0225
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A00225 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 C1 to C8 light hydrocarbons in natural gas in 20 minutes.
- Publication Part Number: A00226
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A00226 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates C1 to C4 substituted benzenes in ten minutes.
- Publication Part Number: A00013
- Created: 31 Oct 2011
- 467 KB
Publication Part Number | A00013 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates 35 C1 - C7 oxygenated compounds in a sample of botanical air in 42 minutes.
- Publication Part Number: A01615
- Created: 31 Oct 2011
- 793 KB
Publication Part Number | A01615 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates 27 C1 to C7 oxygenated compounds in a hydrocarbon matrix in 42 minutes.
- Publication Part Number: A01614
- Created: 31 Oct 2011
- 782 KB
Publication Part Number | A01614 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with the Agilent J&W PoraBOND Q separates eight substituted benzenes and MTBE in 23 minutes.
- Publication Part Number: A01904
- Created: 01 Oct 2011
- 996 KB
Publication Part Number | A01904 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|