Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates alcohols in blood/plasma in three minutes.
- Publication Part Number: A01323
- Created: 25 Aug 2015
- 392 KB
Publication Part Number | A01323 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of THT and TBM in natural gas in under two minutes using an Agilent J&W Lowox column.
- Publication Part Number: A02248
- Created: 31 Oct 2011
- 820 KB
Publication Part Number | A02248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC analysis THT and MES in natural gas in three minutes, using an Agilent J&W Lowox column.
- Publication Part Number: A02249
- Created: 31 Oct 2011
- 823 KB
Publication Part Number | A02249 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- Publication Part Number: A02037
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02037 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates 26 solvents in DMSO in 27 minutes.
- Publication Part Number: A01424
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01424 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraPLOT Q-HT column separates nine C1 to C4 hydrocarbons in 12 minutes.
- Publication Part Number: A01299
- Created: 31 Oct 2011
- 690 KB
Publication Part Number | A01299 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Agilent J&W Select Al2O3 MAPD is extensively deactivated for a high response to trace polar hydrocarbons, including acetylenes and dienes, in propylene analysis.
- Publication Part Number: A02038
- Created: 31 Oct 2011
- 701 KB
Publication Part Number | A02038 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraBOND Q column separates nine C1 to C3 hydrocarbons in ten minutes.
- Publication Part Number: A01425
- Created: 31 Oct 2011
- 678 KB
Publication Part Number | A01425 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W Lowox column separates 27 C1 to C7 oxygenated compounds in a hydrocarbon matrix in 42 minutes.
- Publication Part Number: A01614
- Created: 31 Oct 2011
- 782 KB
Publication Part Number | A01614 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W VF-23ms column separates eight alditol acetates in nine minutes.
- Publication Part Number: A01968
- Created: 31 Oct 2011
- 628 KB
Publication Part Number | A01968 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of two acrylate odorants in natural gas using an Agilent J&W Lowox multilayer column, in under two minutes.
- Publication Part Number: A02250
- Created: 31 Oct 2011
- 877 KB
Publication Part Number | A02250 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Selectivity of the Agilent J&W Select Al2O3 MAPD column is very high in the separation of seven impurities in a hydrocarbon stream.
- Publication Part Number: A02039
- Created: 31 Oct 2011
- 450 KB
Publication Part Number | A02039 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Selectivity of the Agilent J&W Select Al2O3 MAPD column is very good for separating impurities in 1,3 butadiene by GC.
- Publication Part Number: A02043
- Created: 31 Oct 2011
- 740 KB
Publication Part Number | A02043 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Al2O3/Na2SO4 column separates C2 to C4 hydrocarbons in a light hydrocarbon stream in 27 minutes, with complete separation at elevated temperature.
- Publication Part Number: A01512
- Created: 31 Oct 2011
- 840 KB
Publication Part Number | A01512 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates seven glycols and glycerols in eight minutes.
- Publication Part Number: A0770
- Created: 31 Oct 2011
- 522 KB
Publication Part Number | A00770 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates eight permanent gases in coke oven gas (detarred) in less than ten minutes.
- Publication Part Number: A0763
- Created: 31 Oct 2011
- 506 KB
Publication Part Number | A00763 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column identifies acetylene in ethylene in eight minutes.
- Publication Part Number: A01433
- Created: 31 Oct 2011
- 471 KB
Publication Part Number | A01433 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of impurities in hydrocarbons is achieved in 12 minutes using the Agilent J&W Select Al2O3 MAPD column.
- Publication Part Number: A02041
- Created: 31 Oct 2011
- 832 KB
Publication Part Number | A02041 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates five C2 to C5 volatile amino alcohols in water in ten minutes.
- Publication Part Number: A0163
- Created: 31 Oct 2011
- 545 KB
Publication Part Number | A00163 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates seven C3 to C8 ketones in 10 minutes.
- Publication Part Number: A0682
- Created: 31 Oct 2011
- 445 KB
Publication Part Number | A00682 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|