Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Injection Technique
-
- Instrument
Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column separates trace oxygenates in propylene in less than nine minutes.
- Publication Part Number: A01360
- Created: 31 Oct 2013
- 515 KB
Publication Part Number | A01360 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Agilent J&W PLOT PT columns with permanent integral traps show no spikes, indicating effective particle retention, have no potential for leaks and the ends can be trimmed.
- Publication Part Number: 5991-2975EN
- Created: 26 Aug 2013
- 638 KB
Publication Part Number | 5991-2975EN | ||||||||
---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||||
Instrument |
|
||||||||
Analytical Technique | Technique |
|
|||||||
Injection |
|
||||||||
Detection |
|
||||||||
Sample | Chemical Group |
|
|||||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机An Agilent 7890 Series GC configured with an HPLI with post-column backflushing improves the analysis of trace hydrocarbon impurities in monomer grade 1,3-Butadiene.
- Publication Part Number: 5991-1672EN
- Created: 18 Dec 2012
- 1 MB
Publication Part Number | 5991-1672EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
An improved gas chromatographic method based on a 7890 Series GC for the analysis of trace hydrocarbon impurities in monomer grade 1, 3-Butadiene has been developed.
- Publication Part Number: 5991-1499EN
- Created: 29 Nov 2012
- 2 MB
Publication Part Number | 5991-1499EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 15 C1 to C6 hydrocarbon impurities in propylene in 15 minutes.
- Publication Part Number: A01098
- Created: 31 Oct 2011
- 738 KB
Publication Part Number | A01098 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SilicaPLOT column separates cyclopropane in propylene in 15 minutes.
- Publication Part Number: A01261
- Created: 31 Oct 2011
- 518 KB
Publication Part Number | A01261 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 21 C1 to C6 hydrocarbon impurities in cis-2-butene in 20 minutes.
- Publication Part Number: A01099
- Created: 31 Oct 2011
- 673 KB
Publication Part Number | A01099 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C5 hydrocarbons in exhaust from a gasoline engine in 42 minutes.
- Publication Part Number: A00739
- Created: 31 Oct 2011
- 765 KB
Publication Part Number | A00739 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 15 C1 to C6 hydrocarbon impurities in cis-2-butene in 20 minutes.
- Publication Part Number: A01100
- Created: 31 Oct 2011
- 550 KB
Publication Part Number | A01100 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of C1 to C4 hydrocarbons is achieved in 15 minutes using the Agilent J&W Select Al2O3 MAPD.
- Publication Part Number: A02042
- Created: 31 Oct 2011
- 990 KB
Publication Part Number | A02042 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column indentifies 13 C1 to C6 hydrocarbon impurities in 1,3-butadiene in 15 minutes.
- Publication Part Number: A01121
- Created: 31 Oct 2011
- 535 KB
Publication Part Number | A01121 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 20 components in a hydrocarbon text mix in ten minutes.
- Publication Part Number: A01124
- Created: 31 Oct 2011
- 704 KB
Publication Part Number | A01124 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 15 C1 to C4 hydrocarbons in 24 minutes.
- Publication Part Number: A01294
- Created: 31 Oct 2011
- 968 KB
Publication Part Number | A01294 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 22 C1 to C9 hydrocarbons and C6 to C9 aromatics from a BMW car exhaust in 45 minutes.
- Publication Part Number: A0612
- Created: 31 Oct 2011
- 791 KB
Publication Part Number | A00612 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Low levels of ethylene, propylene and methanol in cooling water are separated by gas chromatography and an Agilent J&W PoraPLOT Q column in 16 minutes.
- Publication Part Number: A01436
- Created: 31 Oct 2011
- 554 KB
Publication Part Number | A01436 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 18 saturated and unsaturated C1 to C6 hydrocarbons in seven minutes.
- Publication Part Number: A0121
- Created: 31 Oct 2011
- 616 KB
Publication Part Number | A00121 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|