必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separate six alcohols and glycols in a water sample in seven minutes.
- Publication Part Number: A01330
- Created: 30 Nov 2015
- 860 KB
Publication Part Number | A01330 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column quantifies the anti-convulsant valproic acid in serum in five minutes.
- Publication Part Number: A00446
- Created: 25 Aug 2015
- 345 KB
Publication Part Number | A00446 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 19 chlorinated solvents in 12 minutes.
- Publication Part Number: A01415
- Created: 31 Oct 2013
- 501 KB
Publication Part Number | A01415 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W Lowox column separates trace oxygenates in propylene in less than nine minutes.
- Publication Part Number: A01360
- Created: 31 Oct 2013
- 515 KB
Publication Part Number | A01360 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates five C5 to C7 cyclic alcohols in eight minutes.
- Publication Part Number: A0177
- Created: 31 Oct 2011
- 480 KB
Publication Part Number | A00177 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with packed, custom-made Agilent J&W CP-Sil 58, separates 13 C14 to C24 fatty acid methyl esters in groundnut oil in 120 minutes.
- Publication Part Number: A0201
- Created: 31 Oct 2011
- 524 KB
Publication Part Number | A00201 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates five C2 to C7 halogenated hydrocarbons in five minutes.
- Publication Part Number: A00017
- Created: 31 Oct 2011
- 460 KB
Publication Part Number | A00017 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 21 C12 to C24 fatty acid methyl esters in fish oil in 20 minutes.
- Publication Part Number: A0169
- Created: 31 Oct 2011
- 547 KB
Publication Part Number | A00169 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 15 C2 to C18 free fatty acids in 14 minutes.
- Publication Part Number: A0126
- Created: 31 Oct 2011
- 654 KB
Publication Part Number | A00126 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of nitrosamines according to EPA 8270 uses the stabilized 50% phenyl PDMS of an Agilent J&W VF-17ms column.
- Publication Part Number: A02296
- Created: 31 Oct 2011
- 702 KB
Publication Part Number | A02296 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 11 solvents in four minutes.
- Publication Part Number: A0438
- Created: 31 Oct 2011
- 718 KB
Publication Part Number | A00438 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates four C1 to C4 formates in two minutes.
- Publication Part Number: A00018
- Created: 31 Oct 2011
- 499 KB
Publication Part Number | A00018 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates five C6 to C9 aromatic hydrocarbons in seven minutes.
- Publication Part Number: A0198
- Created: 31 Oct 2011
- 464 KB
Publication Part Number | A00198 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates 23 C6 to C10 substituted aromatics and phenols in 19 minutes.
- Publication Part Number: A0197
- Created: 31 Oct 2011
- 662 KB
Publication Part Number | A00197 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with custom-made, packed Agilent J&W CP-Sil 34, separates 10 anticonvulsant drugs in serum in 15 minutes.
- Publication Part Number: A0142
- Created: 31 Oct 2011
- 653 KB
Publication Part Number | A00142 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with custom-made, packed Agilent J&W CP-Sil 84, separates a mixture of C14 to C22 fatty acid methyl esters in 120 minutes.
- Publication Part Number: A0130
- Created: 31 Oct 2011
- 660 KB
Publication Part Number | A00130 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 52 CB column separates 15 C3 to C10 ketones in ten minutes.
- Publication Part Number: A0178
- Created: 31 Oct 2011
- 637 KB
Publication Part Number | A00178 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of halogenated pesticides uses direct injection and the stabilized 50% phenyl PDMS of an Agilent J&W VF-17ms column.
- Publication Part Number: A02297
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A02297 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates ten phthalate esters and alcohols in 13 minutes.
- Publication Part Number: A00019
- Created: 31 Oct 2011
- 411 KB
Publication Part Number | A00019 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|