Refine Results
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column identifies cholesterol and C48 to C56 triglycerides in egg yolk in 16 minutes.
- Publication Part Number: A0240
- Created: 31 Oct 2011
- 359 KB
Publication Part Number | A00240 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 11 sterols in tuna oil as TMS derivatives in 17 minutes.
- Publication Part Number: A0314
- Created: 31 Oct 2011
- 397 KB
Publication Part Number | A00314 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates eight C28 to C56 triglycerides in hydrogenated butter fat in 30 minutes.
- Publication Part Number: A0250
- Created: 31 Oct 2011
- 933 KB
Publication Part Number | A00250 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-TAP CB for Glycerides column separates 11 components in butter fat in 29 minutes.
- Publication Part Number: A0223
- Created: 31 Oct 2011
- 765 KB
Publication Part Number | A00223 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Determine cholesterol, beta-sitosterol and stigmasterol in butter fat by GC with an Agilent J&W VF-5ms column.
- Publication Part Number: A02255
- Created: 31 Oct 2011
- 947 KB
Publication Part Number | A02255 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of sterols in rapeseed oil as silyl derivatives by gas chromatography with Agilent J&W VF-5ht columns in 11 minutes.
- Publication Part Number: A02423
- Created: 11 May 2010
- 982 KB
Publication Part Number | A02423 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of sterols in sunflower oil as silyl derivatives by gas chromatography with Agilent J&W VF-5ht columns in 12 minutes.
- Publication Part Number: A02421
- Created: 11 May 2010
- 705 KB
Publication Part Number | A02421 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of sterols in olive oil as silyl derivatives by gas chromatography with Agilent J&W VF-5ht columns in 12 minutes.
- Publication Part Number: A02422
- Created: 11 May 2010
- 660 KB
Publication Part Number | A02422 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|