Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机Agilent J&W PLOT PT columns with permanent integral traps show no spikes, indicating effective particle retention, have no potential for leaks and the ends can be trimmed.
- Publication Part Number: 5991-2975EN
- Created: 26 Aug 2013
- 638 KB
Publication Part Number | 5991-2975EN | ||||||||
---|---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||||
Instrument |
|
||||||||
Analytical Technique | Technique |
|
|||||||
Injection |
|
||||||||
Detection |
|
||||||||
Sample | Chemical Group |
|
|||||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
Publication Part Number | SI-02644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 14 C1 to C6 hydrocarbon impurities in 1,3-butadiene in 15 minutes.
- Publication Part Number: A01122
- Created: 31 Oct 2011
- 424 KB
Publication Part Number | A01122 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column separates 20 C1 to C6 hydrocarbons in a reference mixture in 15 minutes.
- Publication Part Number: A01123
- Created: 31 Oct 2011
- 565 KB
Publication Part Number | A01123 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-AL2O3/Na2SO4 column separates butenes in a butane stream in 22 minutes.
- Publication Part Number: A01513
- Created: 31 Oct 2011
- 646 KB
Publication Part Number | A01513 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 20 components in a hydrocarbon text mix in ten minutes.
- Publication Part Number: A01124
- Created: 31 Oct 2011
- 704 KB
Publication Part Number | A01124 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 22 saturated and unsaturated light hydrocarbons in 20 minutes.
- Publication Part Number: A00037
- Created: 31 Oct 2011
- 480 KB
Publication Part Number | A00037 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-SilicaPLOT column separates cyclopropane in propylene in 15 minutes.
- Publication Part Number: A01261
- Created: 31 Oct 2011
- 518 KB
Publication Part Number | A01261 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates eight C1 to C3 hydrocarbons in ten minutes.
- Publication Part Number: A0451
- Created: 31 Oct 2011
- 657 KB
Publication Part Number | A00451 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 39 C1 to C4 nitriles and C1 to C5 hydrocarbons in 60 minutes.
- Publication Part Number: A00572
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00572 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 components in a sample of liquid petroleum gas in three minutes.
- Publication Part Number: A00038
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A00038 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates six C1 to C3 hydrocarbons and polar volatiles in five minutes.
- Publication Part Number: A0686
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00686 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates 10 hydrocarbons in three minutes.
- Publication Part Number: A00581
- Created: 31 Oct 2011
- 536 KB
Publication Part Number | A00581 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT S column separates eight C1 to C3 hydrocarbons in 10 minutes.
- Publication Part Number: A0452
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A00452 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten impurities in propylene in 14 minutes.
- Publication Part Number: A0714
- Created: 31 Oct 2011
- 601 KB
Publication Part Number | A00714 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- Publication Part Number: A02037
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02037 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Select 624 CB column separates 25 impurities in 1,3-butadiene for an ASTM method, in 30 minutes.
- Publication Part Number: A01544
- Created: 31 Oct 2011
- 612 KB
Publication Part Number | A01544 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 111components during naphtha and reformate according to ASTM D5134 in 75 minutes.
- Publication Part Number: A0752
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00752 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD is extensively deactivated for a high response for GC trace analysis of 14 polar hydrocarbons, including acetylenes and dienes.
- Publication Part Number: A02044
- Created: 31 Oct 2011
- 864 KB
Publication Part Number | A02044 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight C1 to C3 hydrocarbons in 10 minutes.
- Publication Part Number: A0453
- Created: 31 Oct 2011
- 639 KB
Publication Part Number | A00453 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|