Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Chemical Group
-
- Compounds
-
Compounds
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates ten C4 to C12 amines in 30 minutes.
- Publication Part Number: A01253
- Created: 31 Oct 2011
- 560 KB
Publication Part Number | A01253 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography of 12 standard volatile aliphatic amines in fish is achieved in 2.5 minutes using an Agilent J&W CP-Sil 8 CB for Amines column.
- Publication Part Number: A01435
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01435 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates six C2 to C5 amino alcohols in 30 minutes.
- Publication Part Number: A01254
- Created: 31 Oct 2011
- 414 KB
Publication Part Number | A01254 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates di- and trialkylamines in 45 minutes.
- Publication Part Number: A01277
- Created: 31 Oct 2011
- 367 KB
Publication Part Number | A01277 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates 14 monoalkylamines in 45 minutes.
- Publication Part Number: A01276
- Created: 31 Oct 2011
- 433 KB
Publication Part Number | A01276 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates three ethanolamines in 25 minutes.
- Publication Part Number: A01538
- Created: 31 Oct 2011
- 400 KB
Publication Part Number | A01538 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column separates 14 amines in 40 minutes to demonstrate the linearity of amine elution.
- Publication Part Number: A01275
- Created: 31 Oct 2011
- 554 KB
Publication Part Number | A01275 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates five phenols in 25 minutes, with sharp peaks.
- Publication Part Number: A01541
- Created: 31 Oct 2011
- 485 KB
Publication Part Number | A01541 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Amines column determines trace levels of amines in 25 minutes.
- Publication Part Number: A01278
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A01278 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|