Refine Results
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
- Chemical Group
-
Chemical Group
- Language
-
Language
Applied Filters
Describing the detailed separation of C1-C5 Light Hydrocarbons on CP-Al2O3/Na2SO4.
- Publication Part Number: SI-02644
- Created: 27 Sep 2012
- 150 KB
Publication Part Number | SI-02644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 24 C1 to C5 hydrocarbons in 27 minutes.
- Publication Part Number: A0611
- Created: 31 Oct 2011
- 957 KB
Publication Part Number | A00611 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column separates 20 C1 to C6 hydrocarbons in a reference mixture in 15 minutes.
- Publication Part Number: A01123
- Created: 31 Oct 2011
- 565 KB
Publication Part Number | A01123 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C1 to C4 light hydrocarbons in 20 minutes.
- Publication Part Number: A00591
- Created: 31 Oct 2011
- 376 KB
Publication Part Number | A00591 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 20 components in a hydrocarbon text mix in ten minutes.
- Publication Part Number: A01124
- Created: 31 Oct 2011
- 704 KB
Publication Part Number | A01124 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates a mixture of butenes in just over 30 minutes.
- Publication Part Number: A00021
- Created: 31 Oct 2011
- 479 KB
Publication Part Number | A00021 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column resolves 21 C1 to C6 hydrocarbon impurities in cis-2-butene in 20 minutes.
- Publication Part Number: A01099
- Created: 31 Oct 2011
- 673 KB
Publication Part Number | A01099 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 14 components in a sample of liquid petroleum gas in three minutes.
- Publication Part Number: A00038
- Created: 31 Oct 2011
- 582 KB
Publication Part Number | A00038 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD 0.53 mm column is highly deactivated, with an excellent response when analyzing trace polar hydrocarbons, including acetylenes and dienes, in
- Publication Part Number: A02037
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02037 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W CP-Al2O3/Na2SO4 column separates C2 to C4 hydrocarbons in a light hydrocarbon stream in 27 minutes, with complete separation at elevated temperature.
- Publication Part Number: A01512
- Created: 31 Oct 2011
- 840 KB
Publication Part Number | A01512 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates six C3 to C4 impurities in 1-butene in 13 minutes.
- Publication Part Number: A00592
- Created: 31 Oct 2011
- 667 KB
Publication Part Number | A00592 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates 16 C3 to C4 impurities in 1,2-butadiene in 20 minutes.
- Publication Part Number: A00594
- Created: 31 Oct 2011
- 774 KB
Publication Part Number | A00594 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column identifies ten impurities in ethylene in ten minutes.
- Publication Part Number: A01125
- Created: 31 Oct 2011
- 471 KB
Publication Part Number | A01125 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column provides fast resolution of 14 C1 to C4 hydrocarbons in less than three minutes.
- Publication Part Number: A01096
- Created: 31 Oct 2011
- 585 KB
Publication Part Number | A01096 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 11 C1 to C4 alkanes and alkenes in 15 minutes.
- Publication Part Number: A00022
- Created: 31 Oct 2011
- 488 KB
Publication Part Number | A00022 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 15 C1 to C6 hydrocarbon impurities in cis-2-butene in 20 minutes.
- Publication Part Number: A01100
- Created: 31 Oct 2011
- 550 KB
Publication Part Number | A01100 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates ten impurities in propylene in 14 minutes.
- Publication Part Number: A0714
- Created: 31 Oct 2011
- 601 KB
Publication Part Number | A00714 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机The Agilent J&W Select Al2O3 MAPD is extensively deactivated for a high response for GC trace analysis of 14 polar hydrocarbons, including acetylenes and dienes.
- Publication Part Number: A02044
- Created: 31 Oct 2011
- 864 KB
Publication Part Number | A02044 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/Na2SO4 column indentifies 14 C1 to C6 hydrocarbon impurities in 1,3-butadiene in 15 minutes.
- Publication Part Number: A01122
- Created: 31 Oct 2011
- 424 KB
Publication Part Number | A01122 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Al2O3/KCl column indentifies 19 C1 to C7 hydrocarbons in 63 minutes.
- Publication Part Number: A0896
- Created: 31 Oct 2011
- 746 KB
Publication Part Number | A00896 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|