必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight C2 to C7 free fatty acids in water in seven minutes.
- Publication Part Number: A0281
- Created: 20 June 2014
- 711 KB
Publication Part Number | A00281 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Agilent's new deactivation of the 6% cyanopropyl dimethylpolysiloxane (624) phase significantly improves acid performance and maintains very good performance.
- Publication Part Number: 5991-0845EN
- Created: 31 July 2012
- 2 MB
Publication Part Number | 5991-0845EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (United States) | Complete (PDF) |
---|
必威体育登录手机The Agilent J&W VF-200ms trifluoropropyl phase is very stable for analyzing aggressive compounds.Thick film loadability is much higher, as shown in more symmetrical peaks for
- Publication Part Number: A02214
- Created: 31 Oct 2011
- 664 KB
Publication Part Number | A02214 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column, with special acid treatment, separates several free fatty acids in five minutes.
- Publication Part Number: A00077
- Created: 31 Oct 2011
- 416 KB
Publication Part Number | A00077 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Wax 57 CB column separates 22 food flavors and aromas in 80 minutes.
- Publication Part Number: A00085
- Created: 31 Oct 2011
- 861 KB
Publication Part Number | A00085 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates nine C2 to C7 volatile fatty acids in water in 12 minutes.
- Publication Part Number: A0122
- Created: 31 Oct 2011
- 532 KB
Publication Part Number | A00122 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Gas chromatography with an Agilent J&W FFAP column separates eight volatile C2 to C7 free fatty acids in 15 minutes.
- Publication Part Number: A00097
- Created: 31 Oct 2011
- 561 KB
Publication Part Number | A00097 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-FFAP column separates several C2 to C5 free fatty acids in five minutes.
- Publication Part Number: A00078
- Created: 31 Oct 2011
- 574 KB
Publication Part Number | A00078 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Thick film Agilent J&W VF-200ms is very stable for analyzing aggressive compounds.For acetic acid, solubility is relatively high, which results in a narrow peak.
- Publication Part Number: A02203
- Created: 31 Oct 2011
- 544 KB
Publication Part Number | A02203 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Analysis of Organic Acids using Agilent J&W FactorFour VF-WAXms GC Columns
- Publication Part Number: SI-00937
- Created: 08 Oct 2010
- 150 KB
Publication Part Number | SI-00937 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|