Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Compounds
- Language
-
Language
Applied Filters
必威体育登录手机The Agilent J&W VF-5ms low bleed phase is highly efficient and reproducible.It is ideal for oil elution patterns for characterization or ‘fingerprints'.
- Publication Part Number: A01987
- Created: 31 Oct 2011
- 866 KB
Publication Part Number | A01987 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机GC with an Agilent J&W VF-5ms column can be used to characterize oils such as spearmint oil.
- Publication Part Number: A01985
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A01985 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Inertness of the Agilent J&W VF-5ms GC column is very high, as shown in the characterization of ylang-ylang oil by GC.
- Publication Part Number: A01986
- Created: 31 Oct 2011
- 796 KB
Publication Part Number | A01986 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机The Agilent J&W VF-5ms 0.15 mm id fast column reduces run time by half in the analysis of complex essential oils such as lemon oil while maintaining separation.
- Publication Part Number: A02333
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02333 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Using Agilent J&W VF-5ms 0.15 mm id fast columns, the run time of spearmint essential oil can be reduced by a factor of 2, with an identical separation.
- Publication Part Number: A02335
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02335 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Using Agilent J&W VF-5ms 0.15 mm id fast columns, the run time of ylang-ylang essential oil can be reduced by a factor of 2, while the separation is identical.
- Publication Part Number: A02334
- Created: 11 May 2010
- 1 MB
Publication Part Number | A02334 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|