必威体育登录手机The environment of the reactor in a nuclear power plant cnn be checked for the presence of gases with portable Agilent 490 Micro GC with Agilent J&W CP-Molsieve 5Å.
- Publication Part Number: A01621
- Created: 12 Aug 2022
- 241 KB
Publication Part Number | A01621 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Molsieve 5Å column separates eight permanent gases at the ppm level in nine minutes.
- Publication Part Number: A0417
- Created: 10 Mar 2015
- 62 KB
Publication Part Number | A00417 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
A gas chromatography method has been developed for the analysis of natural gas and natural gas liquids by capillary column
- Publication Part Number: 5991-2063eN
- Created: 20 Mar 2013
- 183 KB
Publication Part Number | 5991-2063EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates six permanent gases in six minutes.
- Publication Part Number: A01245
- Created: 31 Oct 2011
- 394 KB
Publication Part Number | A01245 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin film Agilent J&W CP-Molsieve column separates five permanent gases in less than three minutes.
- Publication Part Number: A01246
- Created: 31 Oct 2011
- 434 KB
Publication Part Number | A01246 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates six permanent gases in eight minutes.
- Publication Part Number: A01247
- Created: 31 Oct 2011
- 467 KB
Publication Part Number | A01247 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in less than five minutes using Agilent PLOT columns in tandem,with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02030
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02030 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC/MS using an Agilent J&W PoraPLOT Q column separates 14 reaction products of n-butane formed by CH3 radicals in 20 minutes.
- Publication Part Number: A0755
- Created: 31 Oct 2011
- 549 KB
Publication Part Number | A00755 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates five gases in five minutes.
- Publication Part Number: A0307
- Created: 31 Oct 2011
- 368 KB
Publication Part Number | A00307 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight gases and volatiles in 13 minutes.
- Publication Part Number: A01610
- Created: 31 Oct 2011
- 409 KB
Publication Part Number | A01610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three components in an air sample in two minutes.
- Publication Part Number: A0283
- Created: 31 Oct 2011
- 363 KB
Publication Part Number | A00283 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates five permanent gases in about five minutes.
- Publication Part Number: A00036
- Created: 31 Oct 2011
- 412 KB
Publication Part Number | A00036 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of permanent gases and CO2 is achieved in two minutes using Agilent PLOT columns in tandem, in the Agilent J&W Select Permanent Gases/CO2 format.
- Publication Part Number: A02050
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A02050 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CarboBOND column analyzes carbon dioxide and carbon monoxide in hydrocarbon streams in six minutes.
- Publication Part Number: A01431
- Created: 31 Oct 2011
- 588 KB
Publication Part Number | A01431 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates ten permanent gases and hydrocarbons in 15 minutes.
- Publication Part Number: A0680
- Created: 31 Oct 2011
- 504 KB
Publication Part Number | A00680 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six gases in water solvents in five minutes.
- Publication Part Number: A0439
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00439 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Fast GC analysis of inert gases in less than 150 seconds is achieved using an Agilent J&W PoraPLOT Q column and Agilent 490 Micro GC.
- Publication Part Number: A01633
- Created: 31 Oct 2011
- 407 KB
Publication Part Number | A01633 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CarboPLOT P7 column separates eight permanent gases in coke oven gas (detarred) in less than ten minutes.
- Publication Part Number: A0763
- Created: 31 Oct 2011
- 506 KB
Publication Part Number | A00763 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates gases in a water sample in 10 minutes.
- Publication Part Number: A0992
- Created: 31 Oct 2011
- 535 KB
Publication Part Number | A00992 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent 490 Micro GC with an Agilent J&W CP-Molsieve 5Å analyzes air near a garbage dump for neon, hydrogen, oxygen, nitrogen, methane and carbon monoxide in 240 s.
- Publication Part Number: A01619
- Created: 31 Oct 2011
- 417 KB
Publication Part Number | A01619 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|