必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 for PCB column resolves two polycyclic aromatic hydrocarbons in transformer oil in 50 minutes.
- Publication Part Number: A01101
- Created: 31 Oct 2011
- 426 KB
Publication Part Number | A01101 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for PCBs column separates 12 chlorinated pesticides according to EPA 505 in 23 minutes.
- Publication Part Number: A0778
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00778 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 for PCB column resolves six polycyclic aromatic hydrocarbons in transformer oil in 31 minutes.
- Publication Part Number: A01103
- Created: 31 Oct 2011
- 524 KB
Publication Part Number | A01103 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates polychlorinated biphenyls in six Aroclor PCB mixtures in 30 to 45 minutes.
- Publication Part Number: A0672
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A00672 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for PCBs column separates polychlorinated biphenyls in a standard text mix in 60 minutes.
- Publication Part Number: A0662
- Created: 31 Oct 2011
- 969 KB
Publication Part Number | A00662 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for PCB column separates seven, regulation-relevant polychlorinated biphenyls in 35 minutes.
- Publication Part Number: A01565
- Created: 31 Oct 2011
- 511 KB
Publication Part Number | A01565 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|