Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
- Chemical Group
- Injection Technique
- Language
-
Language
Applied Filters
Polycyclic aromatic hydrocarbons (PAHs) are compounds that contain two or more aromatic rings.They are formed during incomplete combustion or pyrolysis of organic matter
- Publication Part Number: SI-02263
- Created: 01 Nov 2019
- 410 KB
Publication Part Number | SI-02263 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
The difficulty in analyzing polycyclic aromatic hydrocarbons (PAHs) lies in the number of PAHs with the same mass...
- Publication Part Number: SI-2281
- Created: 03 Feb 2014
- 403 KB
Publication Part Number | SI-02281 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for Extra Fast Separation of 16 US EPA 610 Regulated PAHs on Agilent J&W Select PAH
- Publication Part Number: SI-2282
- Created: 30 Jan 2014
- 250 KB
Publication Part Number | SI-02282 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Application note for fast Separation of 27 EU and US EPA Regulated PAHs on Agilent J&W Select PAH
- Publication Part Number: SI-2280
- Created: 29 Jan 2014
- 426 KB
Publication Part Number | SI-02280 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Analyze polycyclic aromatic hydrocarbons with Agilent J&W VF-5ms and oncolumn injection to avoid discrimination, adsorption, or decomposition in hot injection ports.
- Publication Part Number: A02253
- Created: 31 Oct 2011
- 2 MB
Publication Part Number | A02253 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PAH CB UltiMetal column separates 16 polyaromatic hydrocarbons according to EPA 610 in 58 minutes.
- Publication Part Number: A00586
- Created: 31 Oct 2011
- 577 KB
Publication Part Number | A00586 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of 16 polyaromatic hydrocarbons according to EPA 610 is achieved in less than 23 minutes using Agilent J&W VF-5ms EZ-Guard columns.
- Publication Part Number: A02209
- Created: 31 Oct 2011
- 940 KB
Publication Part Number | A02209 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 17 polycyclic aromatic hydrocarbons according to EPA 610 in 60 minutes.
- Publication Part Number: A0704
- Created: 31 Oct 2011
- 597 KB
Publication Part Number | A00704 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|