必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Squalene column separates 76 C1 to C9 aliphatic and cyclic hydrocarbons in naphtha in 45 minutes.
- Publication Part Number: A0433
- Created: 31 Oct 2011
- 931 KB
Publication Part Number | A00433 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Squalene column separates isothermally 76 C1 to C9 aliphatic and cyclic hydrocarbons in naphtha in 28 minutes.
- Publication Part Number: A0434
- Created: 31 Oct 2011
- 912 KB
Publication Part Number | A00434 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 2 CB column separates 111 C4 to C11 hydrocarbons in 49 minutes.
- Publication Part Number: A0903
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00903 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB column separates 81 C1 to C7 hydrocarbons in car exhaust gas in 33 minutes.
- Publication Part Number: A0895
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00895 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 111components during naphtha and reformate according to ASTM D5134 in 75 minutes.
- Publication Part Number: A0752
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00752 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 23 C1 to C7 hydrocarbons in natural gas in 50 minutes.
- Publication Part Number: A0271
- Created: 31 Oct 2011
- 528 KB
Publication Part Number | A00271 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates 33 solvents in 30 minutes.
- Publication Part Number: A01624
- Created: 31 Oct 2011
- 579 KB
Publication Part Number | A01624 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 53 alkanes and C5 to C9 aromatics in 50 minutes.
- Publication Part Number: A00020
- Created: 31 Oct 2011
- 640 KB
Publication Part Number | A00020 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates over 165 C4 to C12 hydrocarbons in 130 minutes.
- Publication Part Number: A00602
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00602 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil PONA CB column separates 31components in unleaded gasoline according to ASTM D5769 in 58 minutes.
- Publication Part Number: A01274
- Created: 31 Oct 2011
- 874 KB
Publication Part Number | A01274 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Ethanol is a key additive in gasoline, serving as both a smog reducer as well as a supplement...
- Publication Part Number: 5990-6650EN
- Created: 20 Oct 2010
- 224 KB
Publication Part Number | 5990-6650EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|