Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Chemical Group
-
- Compounds
-
Compounds
- Injection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机GC with Agilent J&W CP-SilicaPLOT analyzes sulfur (to about 0.05 to 0.1 ppm) and hydrocarbosn in beverage-grade CO2!aromatic and acetaldehyde hydrocarbons < 1 ppbv.
- Publication Part Number: A01644
- Created: 31 Oct 2011
- 385 KB
Publication Part Number | A01644 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates three sulfur contaminants in natural gas in less than ten minutes.
- Publication Part Number: A01625
- Created: 31 Oct 2011
- 308 KB
Publication Part Number | A01625 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates four sulfur contaminants in beverage-grade carbon dioxide in less than nine minutes.
- Publication Part Number: A01626
- Created: 31 Oct 2011
- 425 KB
Publication Part Number | A01626 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using an Agilent J&W CP-Sil 5 CB separates three sulfur gases, hydrogen sulfide, carbonyl sulfide, and methyl mercaptan, from natural gas according to ASTM D5504.
- Publication Part Number: A01643
- Created: 31 Oct 2011
- 531 KB
Publication Part Number | A01643 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with Agilent J&W CP-Sil 8 CB and PFPD is a highly sensitive and selective system capable of detecting a number of elements, 13 of these with ultimate selectivity.
- Publication Part Number: A01608
- Created: 31 Oct 2011
- 4 MB
Publication Part Number | A01608 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
必威体育登录手机Analysis of sulfur and oxygenated compounds on an Agilent J&W Lowox column in 29 minutes.
- Publication Part Number: A02073
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02073 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates trace organic contaminants in ethylene and propylene bulk gas.
- Publication Part Number: A01557
- Created: 31 Oct 2011
- 427 KB
Publication Part Number | A01557 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the analysis of Low-Level Sulfur Compounds in Natural Gas and Propylene Using a Pulsed Flame Photometric Detector
- Publication Part Number: 5990-9215EN
- Created: 20 Oct 2011
- 1 MB
Publication Part Number | 5990-9215EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for the GC analysis of sulfur components in propylene using a pulsed flame photometric detector
- Publication Part Number: 5990-6990EN
- Created: 20 Dec 2010
- 104 KB
Publication Part Number | 5990-6990EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Analysis of trace sulfur compounds using selective detection is straightforward with Agilent J&W CP-SilicaPLOT GC columns.
- Publication Part Number: A02411
- Created: 11 May 2010
- 667 KB
Publication Part Number | A02411 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|