Refine Results
- 必威体育赛事投注
- Applications and Industries
-
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Detection Technique
-
- Injection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机The environment of the reactor in a nuclear power plant cnn be checked for the presence of gases with portable Agilent 490 Micro GC with Agilent J&W CP-Molsieve 5Å.
- Publication Part Number: A01621
- Created: 12 Aug 2022
- 241 KB
Publication Part Number | A01621 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a custom-made Agilent J&W CP-Molsieve 5Å column separates eight permanent gases at the ppm level in nine minutes.
- Publication Part Number: A0417
- Created: 10 Mar 2015
- 62 KB
Publication Part Number | A00417 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机This application note describes the use of an Agilent Micro GC for gas composition analysis during fuel cell research and development and beta testing.
- Publication Part Number: 5991-3364EN
- Created: 01 Dec 2014
- 332 KB
Publication Part Number | 5991-3364EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Application note for the separation of Permanent Gases on a Liquid Phase
- Publication Part Number: SI-02166
- Created: 29 Jan 2014
- 126 KB
Publication Part Number | SI-02166 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
7890B Packed Column Refinery Gas analysis using the G3507A Large Valve Oven
- Publication Part Number: 5991-3535EN
- Created: 25 Nov 2013
- 1 MB
Publication Part Number | 5991-3535EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Complete Refinery Gas analysis in less than 8 minutes using the G3507A Large valve Oven
- Publication Part Number: 5991-3534EN
- Created: 21 Nov 2013
- 254 KB
Publication Part Number | 5991-3534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent J&W CP-Sil 5 CB GC column separates C1 to C4 alkanes, hydrogen sulfide and other components of natural gas
- Publication Part Number: A00001
- Created: 12 Aug 2013
- 537 KB
Publication Part Number | A00001 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
A gas chromatography method has been developed for the analysis of natural gas and natural gas liquids by capillary column
- Publication Part Number: 5991-2063eN
- Created: 20 Mar 2013
- 183 KB
Publication Part Number | 5991-2063EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机A method has been developed for the analysis of permanent gases and hydrocarbons using Agilent Micro-fluidics Capillary Flow Technology (CFT).
- Publication Part Number: 5991-1323EN
- Created: 26 Nov 2012
- 497 KB
Publication Part Number | 5991-1323EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Very fast refinery gas analysis (RGA) is possible with the portable Agilent 490 Micro GC QUAD.This note describes the use of the 490 Micro GC for RGA, with results obtained in about two minutes.
- Publication Part Number: SI-02233
- Created: 11 Sep 2012
- 953 KB
Publication Part Number | SI-02233 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
Publication Part Number | SI-02235 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
This application note demonstrates the capabilities of the COX column with the 490 Micro GC.
- Publication Part Number: 5990-7054EN
- Created: 06 Sep 2012
- 610 KB
Publication Part Number | 5990-7054EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Application note for the analysis of bio-ethanol by gas chromatography
- Publication Part Number: 5990-9927EN
- Created: 27 Mar 2012
- 863 KB
Publication Part Number | 5990-9927EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|
必威体育登录手机This application note shows the analysis of biogas, and related samples, using the Agilent 490 Micro GC Biogas Analyzer.
- Publication Part Number: 5990-9508EN
- Created: 22 Nov 2011
- 253 KB
Publication Part Number | 5990-9508EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|---|
Korean (Korea) | Complete (PDF) |
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in less than 10 minutes using Agilent PLOT columns in tandem, with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02028
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02028 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates ten permanent gases and hydrocarbons in 15 minutes.
- Publication Part Number: A0680
- Created: 31 Oct 2011
- 504 KB
Publication Part Number | A00680 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thick-film Agilent J&W CP-Molsieve column separates six permanent gases in eight minutes.
- Publication Part Number: A01247
- Created: 31 Oct 2011
- 467 KB
Publication Part Number | A01247 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q UltiMetal column separates gases in a water sample in 10 minutes.
- Publication Part Number: A0992
- Created: 31 Oct 2011
- 535 KB
Publication Part Number | A00992 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with a thin-film Agilent J&W CP-Molsieve column separates four permanent gases in five minutes.
- Publication Part Number: A01248
- Created: 31 Oct 2011
- 477 KB
Publication Part Number | A01248 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates eight C1 to C4 hydrocarbons and other gases in six minutes.
- Publication Part Number: A0606
- Created: 31 Oct 2011
- 575 KB
Publication Part Number | A00606 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|