Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
-
- Injection Technique
- Instrument
-
必威体育登录手机Agilent 7683B Automatic Liquid sampler (2)
必威体育登录手机Agilent 7683 Automatic Liquid sampler (1)
Instrument
- Method
-
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Compared to other vendor's columns, Agilent J&W DB-CLP1/DB-CLP2 provides better combinations of faster analysis times and fewer coelutions,
- Publication Part Number: 5991-0615EN
- Created: 02 Aug 2012
- 2 MB
Publication Part Number | 5991-0615EN | |||||||
---|---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||||
Instrument |
|
|||||||
Analytical Technique | Technique |
|
||||||
Injection |
|
|||||||
Detection |
|
|||||||
Sample | Chemical Group |
|
||||||
示例矩陣 |
|
必威体育登录手机Agilent J&W DB-CLP1 and DB-CLP2 columns separated organohalides from water, while enabling reliable detection at and below EU and EPA maximum contaminant levels.
- Publication Part Number: 5991-0207EN
- Created: 29 Mar 2012
- 922 KB
Publication Part Number | 5991-0207EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Application note for sub μg/L Level Analysis of Chlorinated Pesticide and Herbicide Analysis in Water by GC/μECD
- Publication Part Number: 5990-9735EN
- Created: 20 Jan 2012
- 1 MB
Publication Part Number | 5990-9735EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Korean (Korea) | Complete (PDF) |
---|---|
Japanese (Japan) | Complete (PDF) |
Chinese (Simplified) (China) | Complete (PDF) |
必威体育登录手机GC/MS with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates seven polar N-herbicides in 25 minutes.
- Publication Part Number: A01111
- Created: 31 Oct 2011
- 425 KB
Publication Part Number | A01111 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates ten phenoxy herbicides in 34 minutes.
- Publication Part Number: A01230
- Created: 31 Oct 2011
- 405 KB
Publication Part Number | A01230 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB Low Bleed/MS column separates 19 pesticides and herbicides according to EPA 507 in 28 minutes.
- Publication Part Number: A1002
- Created: 31 Oct 2011
- 677 KB
Publication Part Number | A01002 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 12 triazine herbicides in 16 minutes.
- Publication Part Number: A0910
- Created: 31 Oct 2011
- 661 KB
Publication Part Number | A00910 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates 11 triazine herbicides in 30 minutes.
- Publication Part Number: A01227
- Created: 31 Oct 2011
- 372 KB
Publication Part Number | A01227 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB for Pesticides column separates 10 chlorinated herbicides according to EPA 515 and EPA 8150 in 25 minutes.
- Publication Part Number: A0803
- Created: 31 Oct 2011
- 401 KB
Publication Part Number | A00803 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates eight nitrogen-containing herbicides in 30 minutes.
- Publication Part Number: A01229
- Created: 31 Oct 2011
- 358 KB
Publication Part Number | A01229 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 5 CB-MS column separates 19 pesticides and herbicides according to EPA 507 in 37 minutes.
- Publication Part Number: A0911
- Created: 31 Oct 2011
- 719 KB
Publication Part Number | A00911 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 24 CB column separates 11 urea herbicides, derivatized with methyl iodide, in 30 minutes.
- Publication Part Number: A01228
- Created: 31 Oct 2011
- 413 KB
Publication Part Number | A01228 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 8 CB column separates 19 pesticides and herbicides according to EPA 507 in 23 minutes.
- Publication Part Number: A00779
- Created: 31 Oct 2011
- 638 KB
Publication Part Number | A00779 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 13 CB column separates 11 triazine herbicides in 15 minutes.
- Publication Part Number: A0613
- Created: 31 Oct 2011
- 693 KB
Publication Part Number | A00613 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
環境水サンプルのターゲットスクリーニングと新たなデータベースの作成
- Publication Part Number: 5991-1431JAJP
- Created: 07 Mar 2013
- 1 MB
Publication Part Number | 5991-1431EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|