Refine Results
- 必威体育赛事投注
- Applications and Industries
-
Solution Category
- Content Type
-
Content Type
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Compounds
-
Compounds
- Injection Technique
-
- Instrument
-
Instrument
- Method
-
Method
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 21 light hydrocarbons in 25 minutes.
- Publication Part Number: A01456
- Created: 26 Jan 2023
- 383 KB
Publication Part Number | A01456 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Chirasil-DEX CB column separates two N-trifluoroacetyl derivatives of threonine propyl esters in 22 minutes.
- Publication Part Number: A01117
- Created: 19 July 2016
- 54 KB
Publication Part Number | A01117 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent J&W CP-Wax 57 CB column delivers excellent selectivity in the analysis of 25 impurities in an alcoholic beverage in 37 minutes.
- Publication Part Number: A01540
- Created: 30 Nov 2015
- 1 MB
Publication Part Number | A01540 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The Agilent J&W CP-Wax 57 CB phase shows excellent stability and selectivity for the analysis of 14 volatile compounds in water-alcohol mixtures by gas chromatography in 14 mi
- Publication Part Number: A01908
- Created: 30 Nov 2015
- 973 KB
Publication Part Number | A01908 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 42 C1 to C4 nitriles and C1 to C6 hydrocarbons in 35 minutes.
- Publication Part Number: A00571
- Created: 30 Nov 2015
- 423 KB
Publication Part Number | A00571 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Wax 57 CB column identifies nine impurities in potable ethanol in 30 minutes.
- Publication Part Number: A01320
- Created: 30 Nov 2015
- 871 KB
Publication Part Number | A01320 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography and an Agilent J&W CP-Wax 57 CB for Glycols and Alcohols column separate six alcohols and glycols in a water sample in seven minutes.
- Publication Part Number: A01330
- Created: 30 Nov 2015
- 860 KB
Publication Part Number | A01330 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-WAX 57 CB column provides a unique selectivity in the analysis of 20 impurities in a whisky in 37 minutes.
- Publication Part Number: A01539
- Created: 30 Nov 2015
- 1 MB
Publication Part Number | A01539 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
FID detection fatty acid methyl esters (FAME) on a CP-Sil 88 for FAME GC column.
- Publication Part Number: SI-02178
- Created: 10 Nov 2015
- 133 KB
Publication Part Number | SI-02178 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Agilent Flexible Metal Ferrules were better than Siltite ferrules for benzodiazepine peak shape and response by FID.
- Publication Part Number: 5991-1859EN
- Created: 25 Aug 2015
- 1 MB
Publication Part Number | 5991-1859EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Japanese (Japan) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column quantifies the anti-convulsant valproic acid in serum in five minutes.
- Publication Part Number: A00446
- Created: 25 Aug 2015
- 345 KB
Publication Part Number | A00446 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-Sil 19 CB column separates alcohols in blood/plasma in three minutes.
- Publication Part Number: A01323
- Created: 25 Aug 2015
- 392 KB
Publication Part Number | A01323 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Enantiomeric separation of two barbitals by gas chromatography with an J&W Agilent CP-Cyclodextrin-Β-2,3,6-M-19 column is achieved in 20 minutes.
- Publication Part Number: A0497
- Created: 25 Aug 2015
- 309 KB
Publication Part Number | A00497 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Sil 5 CB column separates 30 non-volatile organic acids (BSTFA derivatives) in 28 minutes.
- Publication Part Number: A0254
- Created: 18 May 2015
- 1 MB
Publication Part Number | A00254 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight C2 to C7 free fatty acids in water in seven minutes.
- Publication Part Number: A0281
- Created: 20 June 2014
- 711 KB
Publication Part Number | A00281 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机The exceptional inertness of Agilent J&W DB-5ms Ultra Inert GC columns delivered superior results for basic compounds in a comparison of -5ms phases.
- Publication Part Number: 5991-4626EN
- Created: 13 May 2014
- 224 KB
Publication Part Number | 5991-4626EN | ||||||
---|---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||||
Instrument |
|
||||||
Analytical Technique | Technique |
|
|||||
Injection |
|
||||||
Detection |
|
||||||
Sample | Chemical Group |
|
|||||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent PoraPLOT Q column provides the right selectivity for the fast analysis of alcohol in urine using headspace analysis.
- Publication Part Number: 5991-4408EN
- Created: 08 Apr 2014
- 69 KB
Publication Part Number | 5991-4408EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Agilent PoraPLOT Q column provides the right selectivity for the fast analysis of alcohol in urine using headspace analysis.
- Publication Part Number: 5991-4409EN
- Created: 08 Apr 2014
- 61 KB
Publication Part Number | 5991-4409EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|