Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
-
- Analyzed With
-
- Chemical Group
-
- Detection Technique
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
In the modern protein chemistry laboratory, time and sample are usually in short supply and cannot be wasted
- Publication Part Number: 5988-7031EN
- Created: 09 Jan 2014
- 488 KB
Publication Part Number | 5988-7031EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
This shows the separation of four proteins by anion exchange chromatography using 4 different high salt-containing elution buffers (up to 2 M) for linear and step gradients.
- Publication Part Number: 5990-9614EN
- Created: 01 Aug 2013
- 658 KB
Publication Part Number | 5990-9614EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
Column choice in SEC depends on column resolving range, identified by calibration with standards appropriate to analyte type, molecular weight range, and size in solution.
- Publication Part Number: 5991-2463EN
- Created: 14 May 2013
- 117 KB
Publication Part Number | 5991-2463EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Agilent Captiva Premium PES syringe filters are compared with non-Agilent PES and PVDF syringe filters.
- Publication Part Number: 5991-1308EN
- Created: 26 Oct 2012
- 293 KB
Publication Part Number | 5991-1308EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|
Analysis of globulins in denaturing and non-denaturing conditions using gel filtration chromatography and a ProSEC 300S column
- Publication Part Number: 5990-8141EN
- Created: 06 Sep 2012
- 425 KB
Publication Part Number | 5990-8141EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
A mixture of standard proteins was used to determine the resolution characteristics of the columns...
- Publication Part Number: 5990-8895EN
- Created: 13 Sep 2011
- 703 KB
Publication Part Number | 5990-8895EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
The number of proteins and antibodies in drug development and in clinical phase trials is growing rapidly.
- Publication Part Number: 5989-9899EN
- Created: 25 Nov 2008
- 110 KB
Publication Part Number | 5989-9899EN | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|