Refine Results
- Applications and Industries
-
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
- Chemical Group
-
- Instrument
- Method
- Language
-
Language
Applied Filters
Determination of aromatic hydrocarbons in jet fuel under normal phase HPLC conditions with RI detection, and complies with the IP436/ASTM D6379 method.
- Publication Part Number: 5991-3172EN
- Created: 01 Sep 2016
- 550 KB
Publication Part Number | 5991-3172EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates three C6 to C7 aromatic impurities in cyclohexane in 18 minutes.
- Publication Part Number: A0260
- Created: 31 Oct 2011
- 530 KB
Publication Part Number | A00260 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Select 624 CB column separates 26 pharmacopoeia-specified solvents in 30 minutes.
- Publication Part Number: A01304
- Created: 31 Oct 2011
- 845 KB
Publication Part Number | A01304 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机Application note for meeting the requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems
- Publication Part Number: 5990-9534RU
- Created: 26 Mar 2014
- 806 KB
Publication Part Number | 5990-9534EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Performance evaluation of aromatic hydrocarbons determination according to IP391(2000)/ASTM D6591 methods with the Agilent 1260 Infinity Binary LC system with RID
- Publication Part Number: 5991-3170RU
- Created: 24 Mar 2014
- 302 KB
Publication Part Number | 5991-3170EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|