Refine Results
- Applications and Industries
- Content Type
-
Content Type
- Analyzed With
-
- Compounds
-
Compounds
- Detection Technique
- Instrument
- Language
-
Language
Applied Filters
必威体育登录手机The Agilent ELSD and a PLRP-S column outperformed UV methods by providing a uniform response in the analysis of aspirin and phenacetin.
- Publication Part Number: 5590-8315EN
- Created: 25 Aug 2015
- 276 KB
Publication Part Number | 5990-8315EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Ocycodone and its oxidative metabolites are analyzed by high performance HPLC/MS coupled with chromatographic separation by an Agilent ZORBAX RRHT Stablebond SB-C18 column.
- Publication Part Number: 5990-3815EN
- Created: 05 Feb 2013
- 92 KB
Publication Part Number | 5990-3815EN | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
Sample Matrix |
|
必威体育登录手机HPLC of four analgesics is achieved with an Agilent Polaris C18-Ether column in less than ten minutes.
- Publication Part Number: A02005
- Created: 31 Oct 2011
- 779 KB
Publication Part Number | A02005 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机HPLC analysis of four pain killers is achieved with an Agilent Polaris C18-Ether column in under seven minutes.
- Publication Part Number: A02014
- Created: 31 Oct 2011
- 617 KB
Publication Part Number | A02014 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机An Agilent Polaris C8 HPLC column separates three analgesics in 40 seconds.
- Publication Part Number: A02218
- Created: 31 Oct 2011
- 644 KB
Publication Part Number | A02218 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机An Agilent Polaris C18-A HPLC column separates eight anti-inflammatory and analgesic drugs in eight minutes.
- Publication Part Number: A02217
- Created: 31 Oct 2011
- 724 KB
Publication Part Number | A02217 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机HPLC with an Agilent Polaris C18-A column separates eight acidic anti-inflammatory and analgesic drugs in eight minutes.
- Publication Part Number: A01926
- Created: 01 Oct 2011
- 489 KB
Publication Part Number | A01926 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
Sample Matrix |
|
必威体育登录手机Agilent Pursuit C18 5 µm material in a ChromSep cartridge separates three common analgesics in less than five minutes using HPLC.
- Publication Part Number: A02309
- Created: 11 May 2010
- 877 KB
Publication Part Number | A02309 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Agilent Pursuit C8 5 µm material in a ChromSep cartridge separates three analgesics in less than five minutes.
- Publication Part Number: A02323
- Created: 11 May 2010
- 465 KB
Publication Part Number | A02323 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
Sample Matrix |
|
必威体育登录手机Using Agilent Pursuit C18 5 µm material in a ChromSep cartridge, six bioactive compounds are separated in 16 minutes.
- Publication Part Number: A02325
- Created: 11 May 2010
- 467 KB
Publication Part Number | A02325 | |||||
---|---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||||
Instrument |
|
|||||
Analytical Technique | Technique |
|
||||
Injection |
|
|||||
Detection |
|
|||||
Sample | Chemical Group |
|
||||
Sample Matrix |
|