必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates four solvents in a gas mix in 220 seconds.
- Publication Part Number: A0888
- Created: 31 Oct 2013
- 408 KB
Publication Part Number | A00888 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
Publication Part Number | SI-02235 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机This application note describes a method for fast on-site analysis of mine gases in less than 100 seconds using the Agilent 490 Micro GC.
- Publication Part Number: 5991-0438EN
- Created: 06 June 2012
- 753 KB
Publication Part Number | 5991-0438EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Gas chromatography with a four-channel Agilent 490 Micro GC separates constituents of mine gas, including carbon monoxide, in 120 seconds.
- Publication Part Number: A01789
- Created: 31 Oct 2011
- 614 KB
Publication Part Number | A01789 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Low levels of ethylene, propylene and methanol in cooling water are separated by gas chromatography and an Agilent J&W PoraPLOT Q column in 16 minutes.
- Publication Part Number: A01436
- Created: 31 Oct 2011
- 554 KB
Publication Part Number | A01436 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column identifies the plant hormone ethylene in an air sample in seven minutes.
- Publication Part Number: A01646
- Created: 31 Oct 2011
- 732 KB
Publication Part Number | A01646 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography using Agilent J&W PoraPLOT Q and PoraPLOT Q-HT columns separate 22 C1to C8 hydrocarbons and C1 to C2 halogenated hydrocarbons in 30 minutes.
- Publication Part Number: A01268
- Created: 31 Oct 2011
- 711 KB
Publication Part Number | A01268 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight gases and volatiles in 13 minutes.
- Publication Part Number: A01610
- Created: 31 Oct 2011
- 409 KB
Publication Part Number | A01610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates methane, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0891
- Created: 31 Oct 2011
- 401 KB
Publication Part Number | A00891 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six gases in seven minutes.
- Publication Part Number: A0293
- Created: 31 Oct 2011
- 517 KB
Publication Part Number | A00293 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT U column separates 12 halogenated and oxygenated hydrocarbons in 15 minutes.
- Publication Part Number: A00599
- Created: 31 Oct 2011
- 775 KB
Publication Part Number | A00599 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates ten permanent gases and hydrocarbons in 15 minutes.
- Publication Part Number: A0680
- Created: 31 Oct 2011
- 504 KB
Publication Part Number | A00680 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates halogenated hydrocarbons and C2 hydrocarbons in 15 minutes.
- Publication Part Number: A01356
- Created: 31 Oct 2011
- 634 KB
Publication Part Number | A01356 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C9 hydrocarbons in air in 60 minutes.
- Publication Part Number: A00056
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00056 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates halogenated hydrocarbons in air in 250 seconds.
- Publication Part Number: A01340
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01340 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates acetylene, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0892
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A00892 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 22 C1 to C9 hydrocarbons and C6 to C9 aromatics from a BMW car exhaust in 45 minutes.
- Publication Part Number: A0612
- Created: 31 Oct 2011
- 791 KB
Publication Part Number | A00612 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|