Refine Results
- 必威体育赛事投注
- Applications and Industries
- Content Type
-
Content Type
- Analysis Technique
- Analyzed With
-
Analyzed With
- Chemical Group
-
Chemical Group
- Detection Technique
- Injection Technique
-
- Instrument
- Analysis Platform
-
Product
- Language
-
Language
Applied Filters
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 38 C1 to C8 hydrocarbons in 350 mL of air at Bilthoven, The Netherlands, on 6 December 1990, in 28 minutes.
- Publication Part Number: A00576
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00576 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC using Agilent J&W CP-Al2O3/KCl separates 43 C2 to C8 hydrocarbons in street level urban air in the evening rush hour in a UK winter, in 46 minutes.
- Publication Part Number: A0479
- Created: 30 Oct 2015
- 1 MB
Publication Part Number | A00479 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Using the CIA Advantage is an advanced system for the automated analysis of VOCs in air or gas samples using canisters
- Publication Part Number: 5991-2842EN
- Created: 26 July 2013
- 2 MB
Publication Part Number | 5991-2842EN | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|
Thermal desorption system for on-line monitoring of a complex mix of volatile and very volatile hydrocarbons (ozone Precursors) in air.
- Publication Part Number: 5991-2823EN
- Created: 26 July 2013
- 1 MB
Publication Part Number | 5991-2823EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
490-GC can be used for analyses of mine gas, especially carbon monoxide at low level which is essential for the safety of mine workers.
- Publication Part Number: SI-02235
- Created: 06 Sep 2012
- 642 KB
Publication Part Number | SI-02235 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机This application note describes a method for fast on-site analysis of mine gases in less than 100 seconds using the Agilent 490 Micro GC.
- Publication Part Number: 5991-0438EN
- Created: 06 June 2012
- 753 KB
Publication Part Number | 5991-0438EN | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
Chinese (Simplified) (China) | Complete (PDF) |
---|
必威体育登录手机Separation of 43 volatile organic components in whole air is accomplished using GC/MS and an Agilent J&W PoraPLOT Q-HT column in less than 60 minutes, at 250 oC.
- Publication Part Number: A01505
- Created: 31 Oct 2011
- 611 KB
Publication Part Number | A01505 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates 13 chlorofluorocarbons, ethane, and methane in 15 minutes.
- Publication Part Number: A01252
- Created: 31 Oct 2011
- 603 KB
Publication Part Number | A01252 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column module and Agilent 490 Micro GC separates halogenated hydrocarbons in air in 250 seconds.
- Publication Part Number: A01340
- Created: 31 Oct 2011
- 573 KB
Publication Part Number | A01340 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using Agilent J&W PoraPLOT Q and PoraPLOT Q-HT columns separate 22 C1to C8 hydrocarbons and C1 to C2 halogenated hydrocarbons in 30 minutes.
- Publication Part Number: A01268
- Created: 31 Oct 2011
- 711 KB
Publication Part Number | A01268 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Fast gas chromatography with an Agilent J&W PoraPLOT U column separates six permanent gases in water in four minutes.
- Publication Part Number: A0684
- Created: 31 Oct 2011
- 559 KB
Publication Part Number | A00684 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates eight gases and volatiles in 13 minutes.
- Publication Part Number: A01610
- Created: 31 Oct 2011
- 409 KB
Publication Part Number | A01610 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W CP-SilicaPLOT column separates nine chlorinated volatiles and hydrocarbons in 14 minutes.
- Publication Part Number: A01289
- Created: 31 Oct 2011
- 806 KB
Publication Part Number | A01289 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/Na2SO4 column separates five C1 to C3 hydrocarbons and vinyl chloride in air in 14 minutes.
- Publication Part Number: A00580
- Created: 31 Oct 2011
- 555 KB
Publication Part Number | A00580 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates three components in an air sample in two minutes.
- Publication Part Number: A0283
- Created: 31 Oct 2011
- 363 KB
Publication Part Number | A00283 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W CP-Al2O3/KCl column separates 35 C1 to C9 hydrocarbons in air in 60 minutes.
- Publication Part Number: A00056
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A00056 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC analysis of permanent gases and CO2 is achieved in less than five minutes using Agilent PLOT columns in tandem,with Agilent J&W Select Permanent Gases/CO2.
- Publication Part Number: A02030
- Created: 31 Oct 2011
- 1 MB
Publication Part Number | A02030 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机Gas chromatography using an Agilent J&W PoraBOND Q column separates 13 chlorinated fluorocarbons and C1 to C6 hydrocarbons in 15 minutes.
- Publication Part Number: A01429
- Created: 31 Oct 2011
- 721 KB
Publication Part Number | A01429 | ||||
---|---|---|---|---|---|
Analysis | Analysed with Part No. |
|
|||
Instrument |
|
||||
Analytical Technique | Technique |
|
|||
Injection |
|
||||
Detection |
|
||||
Sample | Chemical Group |
|
|||
示例矩陣 |
|
必威体育登录手机Gas chromatography with an Agilent J&W PoraPLOT Q column separates six gases in water solvents in five minutes.
- Publication Part Number: A0439
- Created: 31 Oct 2011
- 558 KB
Publication Part Number | A00439 | |||
---|---|---|---|---|
Analysis | Analysed with Part No. |
|
||
Instrument |
|
|||
Analytical Technique | Technique |
|
||
Injection |
|
|||
Detection |
|
|||
Sample | Chemical Group |
|
||
示例矩陣 |
|
必威体育登录手机GC with an Agilent 490 Micro GC and Agilent J&W HayeSep A column module separates acetylene, ethylene, ethane, and carbon dioxide in air in 28 seconds.
- Publication Part Number: A0892
- Created: 31 Oct 2011
- 546 KB
Publication Part Number | A00892 | ||
---|---|---|---|
Analysis | Analysed with Part No. |
|
|
Instrument |
|
||
Analytical Technique | Technique |
|
|
Injection |
|
||
Detection |
|
||
Sample | Chemical Group |
|
|
示例矩陣 |
|